Desain Compact Heat Exchanger “Fin and Tube” pada Jalur Pipa Hot Primary Air dengan Pemanfaatan Fluida Panas dari Innert Steam

Putra, Alvian Jorghi Pratama (2016) Desain Compact Heat Exchanger “Fin and Tube” pada Jalur Pipa Hot Primary Air dengan Pemanfaatan Fluida Panas dari Innert Steam. Other thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK PLTU Paiton II adalah perusahaan pembangkit listrik milik swasta di bawah naungan PT. Jawa Power yang terletak di daerah Paiton Probolinggo. Pembangkit listrik ini mempunyai 2 unit boiler yaitu unit 5 & 6 yang masing masing menghasilkan energi listrik sebesar 610 MW. Pembangkit listrik menggunakan batu bara sebagai bahan baku pembakaran didalam furnace boiler. Tujuan dari penulisan ini adalah memanfaatkan steam dari jalur pipa innert steam yang digunakan untuk memanaskan udara dari PA Fan dengan mendesign compact heat exchanger type fin and tube agar batu bara sebagai bahan bakar yang dikirim bersama udara lebih cepat terkirim menuju furnace boiler. Metodologi yang digunakan pada tugas akhir ini antara lain melakukan optimalisasi steam dari jalur innert steam yang awalnya digunakan sebagai flashing saat pulverizer mengalami trip yang bersumber dari Superheater Divison Panel, kemudian steam ini dimanfaatkan sebagai fluida panas pada heat exchanger. Data-data operasi diambil dari suatu perusahaan pembangkit tenaga listrik yaitu pada control room PT Jawa Power yang dijadikan objek studi. Perhitungan design heat exchanger dengan metode ∆TLMTD. Setelah mendapat dimensi yang sesuai dengan panas yang diinginkan, maka dilakukanlah analisa performansi yaitu nilai efektifitas. Hasil yang didapatkan dari penyelesaian studi kasus ini adalah dimensi compact heat exchanger yang memiliki spesifikasi sesuai, dengan panjang fin 2 meter, lebar fin 1 meter dan panjang tube 2 meter. Hasil analisa performansi (efektifitas) terhadap variasi beban yaitu semakin tinggi pembebanan maka nilai efektifitas juga semakin tinggi. Kata kunci : Innert steam, desain compact heat exchanger, fin and tube, ∆TLMTD ABSTRACT Paiton II is a privately owned power generation companies under PT. Jawa Power yang located in Paiton Probolinggo. The power plant has 2 boiler units are units 5 and 6 which respectively produce electrical energy by 610 MW. The power plant uses coal as raw material combustion in boiler furnace. The purpose of this paper is to utilize steam of inert pipelines steam used to heat the air from PA Fan with the design of compact heat exchanger fin and tube type that coal as a fuel that was sent with the air more quickly sent to the furnace boiler. The methodology used in this thesis include optimizing steam from steam inert pathway that was originally used as flashing when pulverizer experiencing trip sourced from superheater Divison Panel, then steam is used as the hot fluid in the heat exchanger. The data is taken from an operating power company that is in the control room PT Jawa Power as object of study. Heat exchanger design calculation methods ΔTLMTD . After obtaining the dimensions corresponding to the desired heat, we conducted performance analysis of a value effectiveness. Results obtained from the settlement of this case study is the dimension of compact heat exchanger which has a corresponding specification, with a fin length of 2 meters, 1 meters wide fin and tube length of 2 meters. The results of the performance analysis (effectiveness) against load variations, namely the higher the load, the value is also higher effectiveness. Keywords: innert steam, design compact heat exchangers, fin and tube, ΔTLMTD

Item Type: Thesis (Other)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Permesinan Kapal > D4 Teknik Perpipaan
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 18 Sep 2018 03:33
Last Modified: 18 Sep 2018 03:35
URI: http://repository.ppns.ac.id/id/eprint/841

Actions (login required)

View Item View Item