Rachmanu, Tri Handika (2016) ANALISA TEGANGAN PIPA MAIN STEAM DARI OUTLET SECONDARY SUPERHEATER MENUJU INLET TURBIN (STUDI KASUS PLTU TEMBILAHAN 2x7 MW). Other thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.
Full text not available from this repository.Abstract
ABSTRAK Pipa main steam terhubung antara outlet secondary superheater dengan inlet turbin. Sistem perpipaan ini memerlukan perhitungan analisa fleksibilitas menggunakan komputer. Analisa dilakukan untuk menjaga agar sistem perpipaan dapat beroprasi dengan aman sesuai dengan batasan pada ASME B31.1. Analisa tegangan pada tugas akhir ini menitik beratkan pada analisa tegangan statis yang meliputi tegangan akibat sustained load, occasional load, dan thermal ekspansi. Dari permasalahan diatas dilakukan analisa dengan membandingkan perhitungan manual dengan hasil running software CAESAR II 5.1. sehingga bias diketahui nilai tegangan sesuai batasan ASME B31.1 code. Hasil yang didapatkan dari analisa ini yaitu perbandingan antara hasil perhitungan manual dan software. Untuk tegangan akibat sustained load selisih terendah terjadi pada segmen 1 dengan hasil perhitungan manual sebesar 1277.88 psi dan hasil software sebesar 2316.9 psi. Sedangkan nilai tegangan tertinggi terjadi pada segmen 2 sebesar 4552.62 psi pada perhitung an manual dan 4099.1 psi pada perhitungan software. Untuk tegangan occasional nilai tegangan tertinggi terjadi pada segmen 2 sebesar 5130.12 psi pada perhitungan manual dan 4221.2 psi pada perhitungan software. Sedangkan nilai tegangan terendah terjadi pada segmen 1 dengan nilai sebesar 1835.17 psi pada perhitungan manual dan 2146.7 psi pada perhitungan software. Untuk tegangan thermal tertinggi terjadi pada node 1 dengan hasil perhitungan manual sebesar 70417 psi dan hasil software sebesar 8314.5 psi. Sedangkan nilai tegangan terendah terjadi pada node 3 dengan perhitungan manul sebesar 4070.02 psi dan hasil software 3142.9 psi. Meskipun demikian semua hasil tegangan baik manual maupun software masih berada pada batasan allowable stress material yang digunakan. Untuk support yang sesuai standart teknis menggunakan guide support dengan arah gaya Y+ dan Z sebanyak 3 unit dengan jarak minimal 102.36 in. Kata kunci : Tegangan, sustained loads, occasional loads, thermal ekspansi, ASME B31.1 ABSTRACK The main steam pipe connected between the secondary superheater outlet to the turbine inlet. The piping system requires the flexibility calculations using computer analysis. Analysis is done to keep the piping system can operate safely in accordance with the limits on ASME B31.1. Stress analysis in this thesis focuses on the analysis of static voltage which includes a voltage due to sustained load, occasional load, and thermal expansion. From the above problems analyzed by comparing the results of running the manual calculation with CAESAR II 5.1 software. so that the bias voltage value corresponding known limitations ASME B31.1 code. Result obtained from this analysis is the comparison between the results of manual calculations and software. Due to sustained load voltage difference occurs in the lowest segment 1 with the results of manual calculations and results amounted to 1277.88 psi software amounted to 2316.9 psi. While the value of the highest voltage occurs in segment 2 of 4552.62 psi on manual calculations and 4099.1 psi on a calculation software. For occasional tension voltage value is highest in segment 2 of 5130.12 psi on manual calculations and 4221.2 psi on a calculation software. While the value of the lowest voltage occurs in segment 1 with a value of 1835.17 psi on manual calculations and 2146.7 psi on a calculation software. For the highest thermal stress occurs at node 1 with the results of manual calculations and results amounted to 70 417 psi software amounted to 8314.5 psi. While the value of the lowest voltage occurs in node 3 with manul calculations and results amounted to 4070.02 psi psi 3142.9 software. Nevertheless all voltages result in both manual and software is still in the allowable stress limits of the material used. To support the corresponding technical standards using a guide support with the force direction Y + and Z 3 units with a minimum distance of 102.36 in. Keyword : Stress, sustained loads, occasional loads, thermal ekspansi, ASME B31.1.
Item Type: | Thesis (Other) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Jurusan Teknik Permesinan Kapal > D4 Teknik Perpipaan |
Depositing User: | Unnamed user with email repository@ppns.ac.id |
Date Deposited: | 17 Sep 2018 03:17 |
Last Modified: | 17 Sep 2018 03:17 |
URI: | http://repository.ppns.ac.id/id/eprint/807 |
Actions (login required)
View Item |