PERENCANAAN INSTALASI POMPA SISTEM PEMADAM KEBAKARAN PADA KMP. PERINTIS 500 DWT

Anang Wahyu, Mahardika (2014) PERENCANAAN INSTALASI POMPA SISTEM PEMADAM KEBAKARAN PADA KMP. PERINTIS 500 DWT. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK KMP PERINTIS 500 DWT merupakan kapal penumpang seperti halnya kapal lain. Kapal ini juga dipasang instalasi pompa sistem pemadam untuk kenyamanan ABK dan para penumpang. Agar instalasi pompa sistem pemadam ini terinstal dengan baik maka digunakan aturan – aturan menurut Standart Nasional Indonesi (SNI) dan National Fire Protection Association (NFPA). Selain itu perhitungan kapasitas pompa untuk memenuhi atau mensuplai kebutuhan sistem harus sesuai dengan standart yang berlaku. Pada tugas akhir ini standart yang digunakan untuk perhitungan kapasitas pompa adalah menurut standart BKI volume III. Untuk menunjang sistem ini dapat berfungsi dengan baik, maka pada tugas akhir ini dilakukan perhitungan kapasitas pompa dan juga perancangan instalasi pompa sistem pemadam kebakaran pada KMP PERINTIS 500 DWT. Dalam perhitungan dan perancangan tersebut nantinya dapat diketahui pula berapa panjang pipa yang di gunakan untuk instalasi pompa sistem pemadam kebakaran ini. Berdasarkan perhitungan daya pompa yang dibutuhkan untuk memenuhi kebutuhan sistem pemadam kebakaran pada KMP Perintis 500 DWT ini adalah 14,85 kW, head pompa 97,44 meter. Sedangkan pada software head pompa diketahui 99,194 meter. Jenis pompa yang digunakan adalah merk CALPEDA jenis pompa sentrifugal. Kemudian panjang instalasi pipa pemadam kebakaran sebesar 465 meter untuk pipa cabang dan 101 meter untuk pipa utama. Kata kunci : Jenis Pompa, Perencanaan daya pompa, Jalur instalasi sistem, Standart SNI, NFPA, dan BKI. ABSTRACT Perintis 500 DWT passenger ship is a passenger ship as well as the other boats. The ship was also fitted to the pump system installation Department for the convenience of the passengers and crew on board. In order for the installation of fire pump system is installed properly and used the rules – the rules according to Standard National Indonesia (SNI) and the National Fire Protection Association (NFPA). In addition to the calculation of the capacity of the pump to meet or supplying the needs of the system must comply with the applicable sandartd. In this final task is the standard used for the calculation of the capacity of the pump is according to standard BKI volume III. To support this system can function properly, it is in this final task performed the calculation capacity of the pump and also the design of fire pump system installation on passenger ship Perintis 500 DWT. In the calculation of the design and later can be known how long the pipe used for the installation of fire fighting system pumps it. Based on the calculation of the pump power required to meet the needs of fire fithing system on passenger ship Perintis 500 DWT is 14,85 kW and head pump is 97,44 meters. And than the result head pump from software is 99,194 meters. Types of pumps used are brands of CALPEDA centrifugal pump type. Then the length of the pipe installation Fire Department of 465 meters for pipeline branch and 101 metres to the main pipeline. Keyword: the type of pump, pump power planning track system installation, SNI standartd, NFPA (National Fire Protection Association), and BKI.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Permesinan Kapal > D3 Teknik Permesinan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 21 Aug 2018 03:58
Last Modified: 21 Aug 2018 04:43
URI: http://repository.ppns.ac.id/id/eprint/8

Actions (login required)

View Item View Item