DESAIN INTEGRATED SYSTEM TOTAL FLOODING FOAM DAN ANALISA FIRE SEVERITY PADA CHEMICAL STORAGE PT. PERTAMINA (PERSERO) REFINERY UNIT IV CILACAP.

Soewandono, Abimantrana Putera (2016) DESAIN INTEGRATED SYSTEM TOTAL FLOODING FOAM DAN ANALISA FIRE SEVERITY PADA CHEMICAL STORAGE PT. PERTAMINA (PERSERO) REFINERY UNIT IV CILACAP. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Gudang bahan kimia milik PT. Pertamina (Persero) Refinery Unit IV Cilacap merupakan tempat penyimpanan bahan kimia flammable dengan skala besar. Didalam gudang bahan kimia PT. Pertamina (Persero) Refinery Unit IV Cilacap belum dilengkapi dengan sistem kebakaran yang efektif. Maka pada kondisi seperti inilah perlu dilakukan perancangan sistem kebakaran aktif dan otomatis agar dapat melindungi area gudang dan sekitarnya, serta analisa fire severity sebagai referensi perancangan proteksi kebakaran pasif apabila diperlukan. Perancangan sistem proteksi kebakaran aktif terdiri dari perancangan instalasi high expansion foam dan detektor, serta perhitungan fire severity yang terdiri dari perhitungan beban api dan waktu paparan api. Dalam perancangan high expansion foam terlebih dahulu kita menentukan kapasitas foam generator yang dibutuhkan untuk mampu menghasilkan foam yang dapat memenuhi ruangan dengan ketinggian rendaman 3,45 m dalam waktu 3 menit.. Setelah itu perancangan dilakukan menentukan kebutuhan foam dan air, menentukan jumlah dan penempatannya detektor, merancang sistem perpipaan, menentukan daya pompa. Untuk analisa fire severity dilakukan dengan menghitung jumlah bahan kimia yang tersimpan serta kondisi ventilasi pada gudang. Media pemadam menggunakan high expansion foam karena proses pemadaman lebih cepat, yang terintegrasi dengan peralatan seperti heat detector, fire alarm control panel, alarm, titik panggil manual, bladder tank, proportioner, deluge valve dan foam generator. Dari perhitungan yang telah dilakukan, kapasitas foam generator yang dibutuhkan 1322 m 3 /min, jumlah foam concentrate yang dibutuhkan yaitu 1480,5 liter, jumlah air yang dibutuhkan yaitu 47870 liter sehingga membutuhkan daya pompa sebesar 14,25 hp. Sedangkan total beban api pada bahan kimia flammable yang tersimpan sebesar 1359,15 MJ/m 2 dan waktu paparan api yang terjadi apabila bahan kimia flammable terbakar adalah 178 menit. Kata kunci : High expansion foam, fire severity, kebakaran , chemical storage ABSTRACT Chemical warehouse belonging to PT. Pertamina (Persero) Refinery Unit IV Cilacap is a flammable chemical storage on a large scale. Inside chemical storage of PT. Pertamina (Persero) Refinery Unit IV Cilacap has not completed effective fire system. In condition like this needed to design active and automatic fire protection system to protect warehouse area and surrounding, and fire severity analysis as a reference design of passive fire protection system if necessary. Design of active fire protection system consists of design high expansion foam installation and detector, and fire severity calculation consists of fire load calculation and time exposure of fire calculation. In designing High Expansion foam, first we decide the foam generator capacity, which capacity is able to produce sufficient foam in order to floods the warehouse by 3,45 meter high in 3 minutes. After that designing to calculate the foam and water needed, determine the number and placement of detector, design pipe system, calculate pump power. Fire severity performed by calculating the amoun6 of chemical stored and the condition of ventilation in storage. The extinguisher media uses high expansion foam because extinguishing process is faster, and integrated with equipment such as heat detector, fire alarm control panel, alarm, manual pull station, bladder tank, proportioner, deluge valve and foam generator. From calculation, the minimum capacity of foam generator is 1322 m 3 /min, the requirement of foam concentrate is 1480,5 liters, total water needs is 47870 liters, and need the pump power is 14,25 hp. Total Fire load in flammable chemical is 1359,15 MJ/m 2 and time exposure if chemicals in case of fire is 178 minute. Keywords : High Expansion Foam, fire severity, fire , chemical storage

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: ?? tkdkk ??
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 14 Sep 2018 03:31
Last Modified: 14 Sep 2018 03:31
URI: http://repository.ppns.ac.id/id/eprint/683

Actions (login required)

View Item View Item