Kesesuaian Rancangan Sistem Air Bersih Pada Gedung Biz Hotel Tegal Berdasarkan British Standard 6700

Rusdi, Ravihasmi Akbar Moslem (2015) Kesesuaian Rancangan Sistem Air Bersih Pada Gedung Biz Hotel Tegal Berdasarkan British Standard 6700. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Tujuan penelitian ini adalah untuk mengetahui kesesuaian dari desain eksisting yang ada pada gedung Biz hotel tegal berdasarkan british standard . Identifikasi dilakukan pada sistem distribusi air bersih yang dibagi menjadi dua yaitu sistem air dingin dan air panas. dimana sistem distribusi pada gedung biz hotel tegal dibagi menjadi tiga yaitu air bersih boster, air bersih gravitasi, dan air panas suplai yang disuplai oleh satu tanki yang berada di roof floor . Penelitian ini merupakan penelitian analisis pada data existing yang mana pada standar british telah diatur mengenai batas kecepatan yaitu sebesar 3 m/s , terutama pada sistem distribusi bahwa nilai progressiv head yang dihasilkan tidak boleh melebihi available head pada desain tersebut. Berdasarkan hasil penelitian dapat disimpulkan bahwa tidak ada spesifikasi sistem air dingin yang dihasilkan dari perhitungan ulang desain existing yang melebihi dari batas-batas yang telah diijinkan oleh standard british. namun pada sistem air panas terjadi progressif head yang terlalu besar hingga melebihi dari available headnya. sehingga harus ada sebuah rekomendasi mengenai perubahan diameter yang akan digunakan. sehingga akhirnya seluruh perangkat dapat sesuai dengan british standard. KataKunci:Air bersih boster, Progessiv Head, British Standar ABSTRAC The purpose of this study was to determine the suitability of existing designs available in the hotel biz building tegal by british standard. Identification was done on the water distribution system is divided into two systems of cold water and hot water. where the distribution system to the building biz tegal divided into three booster clean water, clean water gravity, and a supply of hot water supplied by a tank that was on the roof floor. This research is the analysis of existing data which the British standard has been set regarding the speed limit is equal to 3 m / s, especially in the distribution system that generated the value progressiv head must not exceed the available head on the design. Based on the results of this study concluded that there was no cold water system specifications resulting from the reassessment of existing designs in excess of the limits permitted by British standards. but in the hot water system occur progressively head which is too large to exceed the available headnya. so there should be a recommendation regarding the change in diameter to be used. so that eventually the entire device can be in accordance with British standards. Keyword : booster clean water , progressiv head ,British Standard

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Permesinan Kapal > D4 Teknik Perpipaan
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 10 Sep 2018 03:31
Last Modified: 10 Sep 2018 03:31
URI: http://repository.ppns.ac.id/id/eprint/471

Actions (login required)

View Item View Item