Udyana, Pungky Agil (2015) ANALISA KERUSAKAN PADA INSTALASI MOTOR INDUKSI DI PT.PETROKIMIA GRESIK. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.
Full text not available from this repository.Abstract
ABSTRAK Motor pompa merupakan salah satu motor induksi yang sangat berperan penting di pabrik 2 unit phonska 4 PT.Petrokimia Gresik, dalam kesehariannya motor pompa MP312A-P1 selalu bekerja terus menerus dalam proses produksi pupuk di unit phonska 4, gangguan serta kerusakan yang sering terjadi pada instalasi maupun isolasi kabel pada motor pompa MP312A-P1 menjadi masalah penting yang perlu diperhatikan, Dalam menganalisa sebuah gangguan maupun kerusakan yang terjadi dapat dilakukan dengan cara mencatat spesifikasi motor serta spesifikasi penampang yang ada, melakukan pengamatan pada objek secara langsung, serta melakukan perhitungan berupa pengolahan data dalam menentukan persyaratan instalasi motor induksi yang aman dan efisien. Penyebab kerusakan yang terjadi pada isolasi kabel motor pompa MP312A-P1 diketahui oleh berbagai macam factor-faktor seperti factor pembebanan, factor usia, factor lingkungan serta factor lainnya. Solusi untuk mencegah terjadinya gangguan maupun kerusakan perlu untuk dipelajari seperti dalam menentukan kemampuan hantar arus, ukuran penghantar, pemilihan isolasi, serta perawatan maupun pengecekan yang rutin dilakukan. Kata kunci : Motor pompa22 MP 211, Spesifikasi, Faktor-faktor, Solusi. ABSTRACT Pump motor is one of the induction motor which has an important role in Phonska 4 unit, plant 2 of PT.Petrokimia Gresik. It always works continuously, especially at fertilizer production process in Phonska 4 unit. Because of that, disturbances and damages or any functional failures that occur in the installation and the cable insulation on the 22 MP 211 pump motor, should be awared by everyone. To analyze those disturbances and damages, we can record the motor specifications, record the existing cross-section spesification, observe the objects directly, and also doing a calculation, such as data processing to determine the installation requirements, so the induction motors were safe and efficient. The causes damage of 22 MP 211 pump motor cable insulation are known by some factors, such as load factor, age factor, environmental factors, etc. Based on those analyze result, there’re some kinds of solution to prevent any disturbances and damages that need to be studied, for example : in determining the current-carrying capability, the size of the conductor, insulation election, maintenance and routine checks also should be done. Key word : Pump motor 22 MP 211, Spesification, Factor-factor, Solition
Item Type: | Thesis (Diploma) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Jurusan Teknik Kelistrikan Kapal > D3 Teknik Kelistrikan Kapal |
Depositing User: | Unnamed user with email repository@ppns.ac.id |
Date Deposited: | 30 Aug 2018 02:08 |
Last Modified: | 30 Aug 2018 02:08 |
URI: | http://repository.ppns.ac.id/id/eprint/250 |
Actions (login required)
View Item |