PERENCANAAN SISTEM PEMADAM SPRINKLER SESUAI STANDAR SOLAS DAN NFPA PADA KM. TONASA LINE

Wahyu, Triatmojo (2015) PERENCANAAN SISTEM PEMADAM SPRINKLER SESUAI STANDAR SOLAS DAN NFPA PADA KM. TONASA LINE. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK KM. Tonasa Line merupakan kapal curah bermuatan semen. Seperti halnya kapal yang lain, kapal ini juga dipasang sistem pemadam sprinkler untuk melindungi kapal dari kebakaran. Instalasi sistem pemadam sprinkler menggunakan standar Safety of Life at Sea (SOLAS) edisi 2004 dan National Fire Protection Association (NFPA) edisi 2002. Pada tugas akhir ini akan dilakukan perhitungan mengenai jumlah sprinkler yang harus dipasang. Perhitungan akan mengacu pada standar SOLAS edisi 2004 dan NFPA edisi 2002. Proses perhitungan dilakukan untuk mendapatkan kapasitas pompa serta jumlah panjang dari pipa dan sambungan-sambungannya. Berdasarkan hasil perhitungan maka diketahui kebutuhan jumlah sprinkler untuk sistem pemadam sebanyak 30 buah. Pompa yang digunakan harus memenuhi syarat head total 56.74m, debit 132,77 m 3 /h dan daya 39.09kW. Kebutuhan material pipa utama sistem pemadam sepanjang 47,18m menggunakan pipa schedule 40 NPS 6” berstandar ASME B36.10M dan untuk pipa cabang sprinkler sepanjang 115,63m menggunakan pipa schedule 10 NPS 2 ½ ” berstandar ASTM A795. Kebutuhan untuk fitting berupa elbow 6” sebanyak 9 buah, elbow 2 ½” sebanyak 4 buah, elbow screw 1” sebanyak 10, tee 6x6x2 ½” sebanyak 2, tee 2 ½” sebanyak 7, tee 2 ½”x2 ½”x1” sebanyak 20, reducer 6”x2 ½” sebanyak 1, reducer 2 ½”x1” sebanyak 10, drop nipple sebanyak 30. Kebutuhan valve berupa swing check valve 2 buah dan angle valve 2 buah. Persentase beban sistem pemadam sprinkler terhadap sistem pemadam secara keseluruhan sebesar 48.95%. Kata kunci : Sprinkler, SOLAS, NFPA, debit, head total, daya pompa. ABSTRACT MV. Tonasa Line is a bulk carrier loaded with cement. As any other vessels, the vessel also installed fire sprinkler system to protect the ship from fires potential. Installation of fire sprinkler system appropriate standart of Safety of Life at Sea (SOLAS) 2004 edition and National Fire Protection Association (NFPA) 2002 edition. The final project will be calculated the number of sprinkler to be installed. The calculation will refer to SOLAS 2004 edition and NFPA standart 2002 edition. The function of calculation for get pump capacity as well as number of length the pipe and fittings. Based on calculations it is know sprinkler requirements for extinguishing system amounts 30 pieces. Pump used must be comply the condition total head 43,32m, mass flowrate 132,77 m 3 /h, and power 29,84 kW. The main pipe of extinguishing system 48,32m of length use pipe schedule 40 NPS 6” agree with ASME B36.10M standart and branch pipelines of sprinkler 115,52m of length use pipe schedule 10 NPS 2 ½ ” agree with ASTM A795 standart. Fitting requirement elbow 6” 9 piece, elbow 2 ½ ” 4 piece, elbow screw 1” 10 piece, tee 6x6x2 ½ ” 2 piece, tee 2 ½ ” 7, tee 2 ½”x2 ½”x1” 20 piece, reducer 6”x2 ½” 1 piece, reducer 2 ½”x1” 10 piece, drop nipples 3o piece. Valve requirement swing check valve 2 piece and angle valve 2 piece. Percentage load of sprinkler system from fire protection system about 48.95%. Keyword : Sprinkler, SOLAS, NFPA, mass flowrate, total head, power of the pump.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Permesinan Kapal > D3 Teknik Permesinan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 29 Aug 2018 04:26
Last Modified: 29 Aug 2018 04:26
URI: http://repository.ppns.ac.id/id/eprint/225

Actions (login required)

View Item View Item