Ardiansah, Farizal Reza (2017) IMPLEMENTASI SISTEM MONITORING APAR BERBASIS APLIKASI ANDROID DENGAN METODE QR CODE GUNA OPTIMALISASI APAR DI PPNS. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.
Full text not available from this repository.Abstract
ABSTRAK Kebakaran adalah salah satu bahaya yang ada di banyak tempat, perlu adanya system pencegahan dan penanggulangan kebakaran untuk mengatur bahaya ini. Politeknik Perkapalan Negeri Surabaya adalah salah satu kampus yang menerapkan sistem pencegahan dan penanggulangan kebakaran. Bisa dilihat dari terpasangnya alat pemadam api salah satunya alat pemadam api ringan sesuai dengan peraturan yang berlaku. Alat pemadam ini perlu adanya perawatan agar pada saat terjadi kebakaran, alat tersebut tidak mengalami kendala apapun. Sesuai dengan Peraturan Menteri Tenaga Kerja dan Transmigrasi No. Per. -04/MEN/1980 bahwa alat pemadam api ringan harus dilakukan perawatan minimal 1 tahun sekali. Tim khusus perawatan akan inspeksi guna melihat apakah alat pemadam tersebut masih dalam kondisi baik atau tidak. Namun dengan area yang sangat luas, dan keterbatasan manusia untuk melakukan inspeksi. Banyak alat pemadam api ringan yang tidak terkena inspeksi bahkan yang sudah di inspeksi pun terkadang masih tidak sesuai dengan peraturan. Diperlukan sistem monitoring APAR untuk memastikan bahwa APAR yang telah diinspeksi sesuai dengan peraturan. Apikasi ini membantu untuk melakukan inspeksi dengan mempermudah monitoring APAR. Selain aplikasi untuk monitoring APAR, diperlukan juga alat yang bisa memonitor tekanan APAR guna bila ada kekurangan tekanan, langsung diterima oleh bagian perawatan. Dan semua data mengenai hasil inspeksi dan tekanan akan langsung disimpan di database yang telah dibuat. Keywords : APAR, Inspeksi, Tekanan APAR, ABSRACT Fire is one of the dangers that exist in many places, this hazard need a fire prevention and control system to manage this hazard. Shipbuilding Institute of Polytechnic Surabaya is one campus that implement fire prevention and control system. Can be seen from the installation of fire extinguisher in accordance with applicable regulations. This extinguishers need maintenance in the event of fire, the tool does not experience any constraints. In accordance with Regulation of the Minister of Manpower and Transmigration No. Per. -04 / MEN / 1980 that light fire extinguishers should be treated at least once a year. The special care team will be inspected to see if the extinguishers are still in good condition or not. But with a very large area, and human limitations to conduct inspections. Many light fire extinguishers that are not subject to inspections even those already in inspection are sometimes still incompatible with the regulations. Fire extinguishers monitoring system is required to ensure that Fire etinguishers have been inspected in accordance with the regulations. This program helps to conduct inspections by facilitating monitoring of fire extinguisher. In addition to fire extinguisher monitoring applications, there is also a tool that can monitor fire extinguisher pressure in case of lack of pressure, directly accepted by the maintenance department. And all data about the inspection and pressure results will be directly stored in the database that has been created. Keywords : fire extinguishe,r Inspection, pressure of fire extinguishers,
Item Type: | Thesis (Diploma) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | ?? tkdkk ?? |
Depositing User: | Unnamed user with email repository@ppns.ac.id |
Date Deposited: | 21 Sep 2018 05:37 |
Last Modified: | 21 Sep 2018 05:37 |
URI: | http://repository.ppns.ac.id/id/eprint/1127 |
Actions (login required)
View Item |