PERANCANGAN PROTOTIPE EXHAUST FAN OTOMATIS DENGAN MONITORING SUHU BERBASIS ARDUINO DI BENGKEL MEKANIK

NUGROHO, SEPTIAN (2017) PERANCANGAN PROTOTIPE EXHAUST FAN OTOMATIS DENGAN MONITORING SUHU BERBASIS ARDUINO DI BENGKEL MEKANIK. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Lingkungan kerja fisik adalah segala sesuatu yang berada disekitar pekerja yang dapat mempengaruhi aktivitasnya. Faktor-faktor lingkungan fisik antara lain suhu, udara, kebisingan dan penerangan. Faktor-faktor tersebut bisa terjadi akibat proses dari produksi. Pada Tugas Akhir ini membahas salah satu faktor lingkungan fisik tersebut yaitu suhu dalam ruangan bengkel mekanik. Jika suatu ruangan temperatur suhunya tinggi maka harus menggunakan alat penata udara seperti Exhaust Fan. Exhaust Fan tersebut bekerja untuk membantu mengeluarkan udara panas yang berada pada bengkel mekanik. Prinsip kerja dari exhaust fan otomatis dengan monitoring suhu pada prototipe ini yaitu ketika sensor LM35 sudah mendeteksi suhu maka akan diproses oleh arduino. Jika suhu mengalami kenaikan hingga mencapai set poin maksimal sebesar 34ºC maka fan akan berputar dan LED kuning menyala. Pada saat suhu sudah mulai menurun hingga mencapai set poin minimal yaitu 31ºC maka secara otomatis fan akan berhenti berputar dan LED hijau menyala. LED digunakan sebagai lampu indikator. Hasil dari pembacaan Suhu akan ditampilkan di display. Pada pengujian prototipe yang sudah dilakukan menunjukan kinerja yang bagus dan sesuai dengan program yang diperintahkan. Untuk mengetahui prosentase error maka dilakukan pengukuran suhu menggunakan LM35 dengan Thermometer. Hasil pengukuran suhu dari kedua alat ukur tersebut menunjukkan selisih 1.13ºC. Prosentase error pada saat pengujian kenaikan suhu sebesar 3.47% dan pada saat pengujian suhu turun sebesar 3.47%. Kata Kunci: Sensor LM35, Exhaust Fan, Thermometer, Prosentase Error. ABSTRACT Physical work environment is everything that is around workers that can affect their activities. Physical environment factors include temperature, air, noise and lighting. These factors can occur due to the process of production. This final project discusses one of the physical environmental factors that is the temperature problem in the room mechanical workshop. If a room has a high temperature then it should use an air-temperature device like the exhaust fan. Exhaust Fan is working to help remove hot air that is in mechanical workshop. Working principle of automatic exhaust fan with temperature monitoring on this prototype is when the LM35 sensor has detected the temperature it will be processed by arduino. If the temperature rises to a maximum set point of 34° C then the fan will spin and the yellow LED lights up . At the time the temperature has begun to decline until it reaches the minimum set point that is 31º C then the fan automatically will stop spinning and green LED lights up. LED is used as indicator light. The result of temperature reading will be displayed on the display. When testing the prototype that has been done , shows a good performance and in accordance with the program ordered. To know the percentage of error then do the temperature measurement using LM35 with Thermometer. The temperature measurement results of the two measuring instruments show the difference of 1.13ºC. The percentage error at the time of temperature rise test is 3.47% and at the time of testing the temperature drops by 3.47%. Keywords: LM35 Sensor, Exhaust Fan, Thermometer, Percentage Error.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Kelistrikan Kapal > D3 Teknik Kelistrikan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 20 Sep 2018 05:17
Last Modified: 20 Sep 2018 05:17
URI: http://repository.ppns.ac.id/id/eprint/1018

Actions (login required)

View Item View Item