PROTOTYPE STEAM HEAT AND WATER COOLING SYSTEM PADA TANGKI PRODUK LATEK BERBASIS PLC DAN HMI MENGGUNAKAN METODE FUZZY LOGIC

PROTOTYPE STEAM HEAT AND WATER COOLING SYSTEM ON THE TANK OF LATEX PRODUCTS USING PLC AND HMI AND FUZZY LOGIC METHOD BASED

Safa'at Jaenal (6910040024)


Abstrak

Sistem pengendalian suhu diperlukan untuk menjaga kualitas produk, sehingga produk yang dihasilkan berkualitas bagus. Pada plant latek PT X semua pekerjaan masih membutuhkan pengawasan penuh. Struktur bangunan pabrik yang bertingkat membuat para operator yang terdiri dari 3 orang harus saling berkomunikasi dan bekerja sama dalam mengoperasikan system, pada saat cooling dan heating. System pengendalian suhu produk latek menggunakan sebuah HMI (Human Machine Interface) sebagai system monitoring dan PLC (Programable Logic Control) sebagai kontroler serta penggunaan metode fuzzy logic yang tepat, sehingga mampu menangkap serta memproses keluaran suhu yang diberikan sensor LM 35 dan merespon dengan cepat. PLC akan secara otomatis mengontrol valve sesuai dengan kebutuhan, serta HMI akan memudahkan operator dalam pengambilan data dan melakukan eksekusi. Sistem monitoring pada tangki produk latek melalui HMI dengan range suhu 50 ? 60oc, dengan Hasil pengujian fuzzy logic untuk mengatur kontrol valve. Prototype sistem kontrol pada tangki produk latek dibuat menggunakan 3valve on,off dan 1kontrol valve dengan 3 kondisi yaitu: valve 100%, valve 50%, dan valve 0%. Kata kunci : HMI,(Human machine interface) PLC, Fuzzy Logic, LM35, Kontrol.


Abstract

Temperature control system is needed to maintain the quality of the product, so that the resulting product quality. At the plant latex PT X all the work still needs full control. Storey factory building structure makes the carrier consisting of 3 persons must communicate and cooperate in operating the system, at the time of cooling and heating. Latex product temperature control system using a HMI (Human Machine Interface) as a monitoring system and PLC (Programable Logic Control) controller as well as the use of appropriate methods of fuzzy logic, so as to capture and process the output of a given temperature sensor LM 35 and respond quickly. PLC will automatically control valve in accordance with the needs and HMI will allow the operator to perform data retrieval and execution. The monitoring system on the tank latex products through HMI with a temperature range of 50 - 60 ? C, with the test results to adjust the fuzzy logic control valve. Prototype control system on the tank latex products are made using 3valve on, off and 1kontrol valve with three conditions, namely: 100% valve, valve 50%, and 0% valve. Keywords: HMI (human machine interface) PLC, Fuzzy Logic, LM35, Control.


Detil Peneliti

Dosen Pembimbing 1 :Urip Mudjiono
Dosen Pembimbing 2 : Purwidi Asri

Program Studi : D4 - TEKNIK OTOMASI
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.