OTOMASI BLOWDOWN DAN MONITORING LEVEL AIR SERTA SUHU STEAM TUBE BERBASIS PLC PADA BOILER POLITEKNIK PERKAPALAN NEGERI SURABAYA

BLOWDOWN AUTOMATION AND MONITORING WATER LEVEL AND TEMPERATURE STEAM TUBE BASED PLC ON BOILER SHIPBUILDING INSTITUTE OF POLYTECHNIC SURABAYA

Okta Randi Pradana (6909040022)


Abstrak

Pada dasarnya boiler merupakan suatu wadah yang berfungsi sebagai pemanas air, panas pembakaran boiler dialirkan ke air sampai terbentuk air panas atau steam. Steam pada tekanan tertentu kemudian digunakan untuk mengalirkan panas ke suatu proses. Air adalah media yang digunakan untuk mengalirkan panas ke suatu proses. Jika air didihkan sampai menjadi steam, maka volumenya akan meningkat. Boiler mempunyai sistem pembuangan air yang disebut blowdown. Pengoperasian blowdown pada boiler di Polikteknik Perkapalan Negeri Surabaya masih menggunakan sistem manual. Blowdown adalah suatu proses pembuangan air pada saat Boiler dihidupkan. Blowdown dilakukan untuk menghindari penuhnya air ketika pertama kali boiler dipanaskan yang dapat menyebabkan tumpahnya air atau kebocoran serta meledaknya steam tube pada Boiler. Pada proses blowdown dengan cara manual masih berbahaya karena harus berinteraksi dengan pipa panas, sehingga diperlukan sistem otomatis pada blowdown agar lebih aman. Sistem otomatis pada blowdown menggunakan PLC Panasonic yang akan mengendalikan volume air yang ada di steam tube dengan menggunakan sensor dan valve. Serta PLC dapat memonitoring dengan menampilkan grafik level air dan suhu pada boiler. Sasaran yang akan dicapai adalah bagaimana sistem blowdown pada boiler tersebut dapat digunakan dengan otomatis serta dapat memonitoring keadaan level air serta suhu pada steam tube.


Abstract

Boiler is basically a container that serves as a water heater, boiler combustion heat transferred to water until it becomes heated water or steam. Steam at a certain pressure and then used for transferring heat to a process. Water is the medium that is used for transferring heat to a process. If the boil water until it becomes steam, then the volume will increase. Boiler has a drainage system called blowdown. Operation of the boiler blowdown at Surabaya State Polytechnic Shipping still using manual systems. Blowdown is a process of removing water at the boiler is turned on. Blowdown water to avoid full when first heated boiler which can lead to leaks and spills of water or steam explosion in the boiler tube. In the blowdown process by hand is still dangerous because they have to interact with the heat pipe, so that the necessary automatic blowdown system to make it more secure. Automatic blowdown system using Panasonic PLC will control the volume of water in the steam tube by using a sensor and valve. As well as the PLC can monitor the water level and display graphics on the temperature of the boiler. Target to be achieved is how the boiler blowdown system can be used with automated and can monitor the state of the water level and temperature in the steam tube.


Detil Peneliti

Dosen Pembimbing 1 :Susetiyadi Purwonugroho
Dosen Pembimbing 2 : Muhammad Shah

Program Studi : D4 - TEKNIK OTOMASI
Angkatan : 2009


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.