ANALISA DESAIN EXPANSION LOOP PADA PENGGANTIAN PIPA TRANSFER AMONIAK (NH3) DIAMETER 8 INCHI DARI TANGKI PENYIMPANAN MENUJU PELABUHAN PT.PETROKIMIA GRESIK

DESIGN ANALYSIS OF EXPANSION LOOP IN PIPE TRANSFER AMMONIA (NH3) REPLACEMENT 8INCH DIAMETER FROM STORAGE TANK TO LOADING DOCK

Arwin Dahril Narendra (6812040034)


Abstrak

PT.Petrokimia berencana melakukan penggantian pipa transfer Amoniak berukuran 8? . General Arrangement dan routing pipa dari desain lama akan dirubah. Hal ini tentunya perlu dilakukan analisa khususnya dari sisi fleksibilitas atau tegangan. Pada Tugas Akhir ini dilakukan analisa desain expansion loop pada pipa transfer amoniak 8? dengan menggunakan pemodelan Software CAESAR II.Pemasangan expansion loop diperlukan untuk mengurangi tegangan dan displacement akibat beban ekspansi.Selain itu perlu diperhatikan jenis dan letak support untuk mendukung expansion loop tersebut. Pemodelan yang dilakukan dari penelitian ini adalah dengan memodelkan 2 tipe expansion loop.Pemodelan yang pertama adalah loop dengan bentuk vertical yang mempunyai nilai radius elbow 1,5 x NPS atau 12inchi.Sedangkan untuk jenis kedua yaitu tipe U bend yang mempunyai radius elbow 5 x NPS. Dari hasil analisa menunjukkan bahwa dari kedua tipe desain expansion loop tersebut masih memiliki nilai tegangan dibawah tegangan ijin menurut ASME B31.3.Dari kedua tipe desain tersebut, U bend dengan radius 5 x NPS diketahui memiliki nilai tegangan yang lebih kecil dari pada loop tipe vertical.Sehingga dapat dikatakan dengan radius elbow yang memiliki nilai luasan yang lebih besar maka akan semakin dapat menyerap nilai tegangan.


Abstract

PT.Petrokimia Gresik planning a transfer ammonia pipe diameter 8inch replacement.The General arrangement and routing pipe from the old design will be changed.It?s of course necessary to analyze in particular in terms of flexibility and stress.The purpose of this final project is to analyze the expansion loop design on the ammonia transfer pipe 8inch by using modelling software CAESAR II.The instalation of expansion loop is needed to reduce stress and over displacement due to expansion load.Beside that,the type and location of piping support is important to support the expansion loop. There are Two type of design expansion loop in this project.first model is vertcal loop that have value 12 inchi (1,5 x NPS) radius of elbow.The second model is U bend loop.This loop have a radius 40 inch (5 x NPS) radius of elbow. From the result of analysis, both type of them have stress value bellow allowable stress according to ASME B31.3.U bend type with 5 x NPS elbow radius is known have smaller stress value then vertical loop type.So thah can be said with elbow have the biggest radius, it will be increasingly able to absorb the stress value.


Detil Peneliti

Dosen Pembimbing 1 :Dimas Endro Witjonarko
Dosen Pembimbing 2 : Mardi Santoso

Program Studi : D4 - TEKNIK PERPIPAAN
Angkatan : 2012