Stress Analysis Pipa Demineralized Water Treatment pada Berbagai Mode Operasional Pompa

stress analysis of demineralized water treatment pipe in various operational modes of pumps

Agnesia Larastyawati (6810040026)


Abstrak

Proyek petrochemical pada PT.SAE memiliki jalur perpipaan dengan NPS 14 dan temperatur 80 ?C. Berdasarkan project specification for piping flexibility analysis yang terangkum sebagai standard practice pada proyek tersebut, sistem perpipaan pada suction line pompa 154-P-505A dan 154-P-505B merupakan jalur yang perlu dianalisa tegangannya dengan menggunakan software II Caesar 5.10. Di lain sisi, sistem perpipaan tersebut memiliki dua pompa yang dipasang secara pararel. Salah satu pompa tersebut merupakan pompa standby dan yang lain merupakan pompa yang sedang beroperasi. Sehingga analisa tegangan pada sistem perpipaan ini dilakukan beberapa mode operasi pompa pada software Caesar II 5.10. Mode operasional pompa diterapkan dengan memvariasikan temperatur pada tiap segmen pipa. Namun, berdasarkan hasil pada software bahwa gaya dan momen melebihi nilai allowable loading nozzle API 610. Jadi desain perpipaan tersebut membutuhkan alternatif modifikasi. Modifikasi yang dapat dilakukan yaitu dengan menggunakan sliding teflon pada support atau dengan menambahkan expansion loop. Desain modifikasi dengan expansion loop dapat mereduksi gaya dan momen pada nozzle pompa. Jadi desain modifikasi ini dapat memenuhi syarat API 610 dan ASME B31.3. Dan dengan metode modal analysis dapat diketahui bahwa desain modifikasi dengan expansion loop aman terhadap getaran pompa. Kata kunci: sistem perpipaan, analisa tegangan, modal analysis, nozzle load, piping load


Abstract

Petrochemical project on PT.SAE has a piping system with NPS 14 and design temperature is 80 ?C. Based on project specification for piping flexibility analysis as a standard practice that piping system on suction line of pumps (154-P-505A and 154-P-505B) has to be analyzed by software Caesar II 5.10. On the other side, that piping system has two pumps are installed by parallel. One of pumps is standby pump and the other pump is operating. So, stress analysis on this piping system is needed operating mode of pumps on software Caesar II 5.10. Pumps operating modes be applied to vary the temperature in each segment of the pipeline. But, based on software calculation result that force and moment exceed value of allowable loading nozzle API 610. So, that piping design is needed alternative modification. Some modification can be applied, there are using sliding teflon on support or adding expansion loop pipe. Modification design with expansion loop can reduce force and moment on pump nozzle. So this modification up to standard API 610 and ASME B31.3. Also with modal analysis method can know that modification design with expansion loop is safe to pump vibration. Key word: piping system, stress analysis, modal analysis, nozzle load, piping load


Detil Peneliti

Dosen Pembimbing 1 :Pranowo Sidi
Dosen Pembimbing 2 : Mardi Santoso

Program Studi : D4 - TEKNIK PERPIPAAN
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.