ANALISA REDESAIN PADA CRITICAL LINE HP FLARE DRUM MBF612504 MENUJU HP FLARE STACK FLR618503 (STUDI KASUS UNIT FLARE SYSTEM)

REDESIGN ANALYSIS OF CRITICAL LINE HP FLARE KO DRUM MBF612504 TO HP FLARE STACK FLR618503 (CASE STUDY AT FLARE SYSTEM UNIT)

Fadhila Hikmadiar (6810040021)


Abstrak

Flare system adalah sistem pengaman yang ada di pabrik kilang minyak untuk mengalirkan fluida yang mudah terbakar dan berbahaya. Pada tugas akhir ini dilakukan analisa tegangan sistem perpipaan untuk memperoleh desain yang baik agar dapat beroperasi dengan aman sesuai ASME B31.3. Analisa tegangan pada tugas akhir meliputi tegangan akibat sustained load, tegangan akibat occasional load, tegangan akibat expansion thermal load, dan beban pada nozzle. Metode analisa menggunakan perhitungan manual dan perhitungan software CAESAR II, dan tegangan ijin sesuai ASME B31.3. Perhitungan manual digunakan sebagai pembanding hasil perhitungan software. Hasil dari analisa akan menetukan desain yang baik dan aman untuk beroperasi. Hasil analisa dari desain existing 1 adalah tegangan akibat sustained load, occasional load, dan expansion thermal load tidak melebihi allowable stress, namun desain existing 1 terbukti gagal karena beban pada nozzle flare stack melebihi allowable nozzle load. Pada desain existing 2 tegangan akibat sustained load dan occasional load tidak melebihi allowable stress, namun desain existing 2 terbukti gagal karena tegangan akibat expansion thermal load dan beban pada nozzle flare stack melebihi allowable. Pada desain alternatif tegangan akibat sustained load, occasional load, expansion thermal load dan nozzle load tidak melebihi allowable. Dari analisa ketiga desain, desain yang aman dan dapat diaplikasikan pada flare system adalah desain alternatif.


Abstract

Flare system is a safety system in the oil refinery plant to flow the flammable and dangerous fluid. This final project performed stress analysis of piping systems to obtain a good design that can be used safely according to ASME B31.3. The analysis includes stress due to sustained loads, stress due to occasional loads, stress due to thermal expansion loads, and nozzle loads. Analysis methods using manual calculation and software CAESAR II calculation, and the allowable stress according to ASME B31.3. Manual calculation used for comparison result of software calculation. The results of the analysis will determine the good design and safe to operate. The results of analysis of the existing 1 design are stress due to sustained loads, occasional loads, and thermal expansion loads does not exceed the allowable stress, but the existing 1 design proved unsuccessful because the load on the nozzle flare stack exceeds the allowable nozzle load. In the existing 2 design stress due to sustained load and occasional load does not exceed the allowable stress, but the existing 2 design proved unsuccessful because of stress due to thermal expansion loads and the load on the nozzle flare stack exceeds the allowable. In an alternative design stress due to sustained loads, occasional loads, thermal expansion loads and nozzle load does not exceed the allowable. Of the three designs that have been analyzed, the safest design and can be used in the flare system is an alternative design.


Detil Peneliti

Dosen Pembimbing 1 :George Endri K
Dosen Pembimbing 2 : Adi Wirawan Husodo

Program Studi : D4 - TEKNIK PERPIPAAN
Angkatan : 2010