ANALISA GETARAN PADA LOW PRESSURE - BOILER FEED PUMP PLTGU

VIBRATION ANALYSIS IN LOW PRESSURE GAS AND STEAM POWER PLANT BOILER FEED PUMP

Achmad Sodik (6809040030)


Abstrak

Low pressure ? boiler feed pump merupakan pompa sentrifugal yang digunakan untuk menyuplai cairan (fluida) bertekanan rendah dengan kapasitas 129,3 m3/h dan temperature 138?. Pada low pressure ? boiler feed pump sering ditemui kasus getaran yang melebihi batas sehingga sering terjadi kerusakan seperti missalignment, impeller terkikis dan poros pompa mengalami defleksi/bengkok. Oleh sebab itu perlu dilakukan analisa nilai getaran yang terjadi. Metode pengerjaan pada tugas akhir ini dilakukan dengan cara penentuan persamaan kesetimbangan gerak, dengan mencari nilai natural frekuensi dapat diketahui sistem mengalami resonansi atau tidak. Selanjutnya dihitung respon getaran yang berupa simpangan sudut dan kecepatan yang kemudian menghasilkan nilai rms. Dengan menggunakan alat vibrasi Computatinal system incomparated (CSI) 2130 akan diperoleh domain frekuensi yang juga menghasilkan nilai rms. Kemudian nilai rms tersebut dibandingkan dengan nilai rms hasil perhitungan. Hasil yang didapatkan dari analisa ini yaitu respon getaran yang berupa amplitudo kecepatan memiliki nilai nilai RMS = 0.10 mm/s pada bearing dan nilai RMS = 0.43 mm/s pada impeller getaran torsional, nilai RMS = 0.14 mm/s pada bearing dan dengan RMS = 0.23 mm/s pada impeller getaran lateral. Sesuai dengan International Standart ISO 2372, nilai getaran dikategorikan ?Good? dan memenuhi syarat. Dari hasil pengukuran vibrasi setelah perbaikan proses aligment terlihat bahwa sudah tidak adanya getaran yang berlebih pada titik pengukuran dan semua pengukuran masuk dalam kategori A (good) dan B (Allowable). Kata kunci : amplitudo kecepatan, frekuensi natural, eksitasi, resonansi, respon getaran, root mean square.


Abstract

Low pressure - boiler feed pump is a centrifugal pump is used to supply the fluid (the fluid) low pressure with a capacity of 129.3 m3 / h and temperatures of 138 ? C. At low pressure - boiler feed pump vibration commonly encountered cases that exceed the limit so frequent damage as missalignment, eroded impeller and pump shaft deflection / bending. Therefore it is necessary to analyze the value of vibe going on. A method of works on duty the end of this was done by means of the determination of the equation equilibrium motion, by searching the value of a natural frequency resonance system experience can be known or not. Next calculated response of vibrations which is in the form of a byway angles and the speed with which then produce rms value. By means of a utensil vibrasi computatinal system incomparated ( csl ) 2130 will be gained by the domain of the frequency of which also produce rms value. Then the rms value compared to the value of rms the result of reckoning. The result obtained from the analysis is the response of vibrations which is in the form of the amplitude of the speed of having value value rms = 0.10 mm / s in bearing and value rms = 0.43 mm / s on impeller unsteadiness torsional, the value of rms = 0.14 mm / s in bearing and with rms = 0.23 mm / s on impeller unsteadiness lateral. In accordance with international standart, iso 2372 the value of vibration categorized ?good? and qualified. Of measurement result vibrasi after repair processes are aligment seen that it is the absence of vibration excess at the point of measurement and all the measurement of included in the category a ( good ) and b ( allowable ). Keywords: amplitude velocity, the amplitude the frequency of natural, excitation, resonance, response unsteadiness, root mean square.


Detil Peneliti

Dosen Pembimbing 1 :Adi Wirawan Husodo
Dosen Pembimbing 2 : Muhammad Muhadi Eko Prayitno

Program Studi : D4 - TEKNIK PERPIPAAN
Angkatan : 2009


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.