ANALISA TEGANGAN PADA PIPA UNIT AMMONIA DARI HEAT EXCHANGER 103-C2_N71 KE HIGH TEMPERATURE SHIFT CONVERTER104-D2A_A DENGAN PENDEKATAN SOFTWARE AUTOPIPE V8I

STRESS ANALISYS OF AMMONIA UNIT PIPE FROM HEAT EXCHANGER 103-C2_N71 TO HIGH TEMPERATURE SHIFT CONVERTER 104-D2A_A USING SOFTWARE AUTOPIPE V8I

Andika Catur K (6809040026)


Abstrak

Pembangunan pabrik PKT-5 Bontang tidak akan lepas dari sistem perpipaan, sistem perpipaan ini memerlukan analisa tegangan lebih lanjut terutama pada sistem perpipaan dengan tekanan dan temperatur kerja tinggi. Tugas akhir ini dilakukan dengan tujuan untuk menentukan jumlah penyangga dan posisinya untuk mengoptimalkan desain. Serta menentukan besarnya tegangan pada sistem perpipaan pabrik PKT-5 Bontang akibat sustained loads, occasional loads, dan ekspansi termal sesuai batasan pada standar ASME B31.3. Analisa pada hasil Tugas Akhir ini dilakukan dengan cara metode membandingkan metode perhitungan manual dan software Autopipe V8i dengan mengacu standart yang digunakan yaitu ASME B31.3. Dari hasil analisa ini didapatkan selisih nilai perhitungan manual akibat sustained loads antara 15780.36 psi sampai 16791.42 psi masih lebih kecil dari tegangan ijin sebesar 18350 psi, tegangan akibat occasional loads antara 519.78 psi sampai 1202.25 psi masih lebih kecil dari tegangan ijin sebesar 24405 psi, nilai akibat ekspansi termal adalah 2754.3 psi dan 11650.3 psi masih lebih kecil dari tegangan ijin sebesar 29587 psi. dan penggunaan penyangga berjumlah 10 satuan dari 20 satuan yang ditetapkan.


Abstract

Plant construction Bontang PKT-5 will not be separated from piping systems, piping systems requires further stress analysis of piping systems, especially at the high working pressure and temperature. The final project was conducted in order to determine the amount of buffer and position to optimize the design. And to determine the magnitude of the voltage at the factory piping systems Bontang PKT-5 due to sustained loads, occasional loads, and thermal expansion corresponding limits on ASME B31.3 standards. Analysis of the Final Project is done by comparing the method of calculation methods Autopipe V8i manual and software with reference standard used is ASME B31.3. The analysis of the results obtained manually calculating the difference in value between the loads sustained due 15780.36 psi until 16791.42 psi to still smaller than the allowable stress of 18350 psi, stress due to occasional loads between 519.78 psi to 1202.25 psi is less than allowable stress of 24,405 psi, the value of result thermal expansion is 2754.3 psi until 11650.3 psi and still smaller than the allowable stress of 29 587 psi.dan buffer usage amounted to 10 units from 20 units were established.


Detil Peneliti

Dosen Pembimbing 1 :Sudiyono
Dosen Pembimbing 2 : Agung Purwana

Program Studi : D4 - TEKNIK PERPIPAAN
Angkatan : 2009


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.