ANALISA TEGANGAN PADA SISTEM PERPIPAAN DI SUCTION POMPA P-0204 PADA UNIT ACID GAS REMOVAL

STRESS ANALYSIS OF PIPING SYSTEM IN SUCTION PUMP P-0204 ON ACID GAS REMOVAL UNIT

Juniawan Dwi Prasetya (6809040009)


Abstrak

ABSTRAK Metode analisa pada tugas akhir ini dilakukan dengan cara membandingkan nilai tegangan terbesar hasil analisa software Bently autoPIPE v8i dengan perhitungan manual. Semua perhitungan dan analisa tegangan yang dilakukan mengacu pada standar ASME B31-3, serta untuk menentukan jumlah dan posisi penyangga yang optimal. Hasil yang didapatkan dari analisa ini yaitu nilai tegangan antara metode analisa menggunakan software dan perhitungan manual. Tegangan terbesar akibat sustained loads pada perhitungan manual terjadi pada segmen 1 yaitu sebesar 2817,969 psi (tegangan ijin 19908 psi), sedangkan perhitungan manual pada occasional loads terjadi pada segmen 1 sebesar 6982,99 psi (tegangan ijin 19908 psi) dan ekspansi termal terletak pada segmen 1 sebesar 29995,87 psi (tegangan ijin 30000 psi). Meskipun demikian, semua tegangan yang terjadi masih dalam batasan aman menurut standar ASME B31-3. Mengenai penyangga, hasil analisa menunjukkan jumlah optimal penyangga yang harus terpasang berjumlah 8 (delapan), sehingga didapat desain yang tidak melebihi tegangan ijin. Kata Kunci : tegangan, sustained loads, occasional loads, ekspansi termal, standar ASME B31-3, penyangga


Abstract

ABSTRACT Method of analysis in this thesis is done by comparing the value of the greatest stress analysis software Bently autoPIPE V8i with manual calculations. All calculations and stress analysis is performed based on standards ASME B31-3, as well as to determine the number and the optimal buffer position. Results obtained from this analysis is the value of the stress between the methods of analysis using the software and manual calculations. Greatest stress due to sustained loads on manual calculations occur on segment 1 is equal to 2817.969 psi (19908 psi allowable stress), whereas occasional manual calculations on loads occurs in segment 1 at 6982.99 psi (19 908 psi allowable stress) and the thermal expansion is segment amounted to 29995.87 at 1 psi (allowable stress 30,000 psi). Nevertheless, all the stress that occurs still in safe limits by the standards of ASME B31-3. Regarding the buffer, the analysis indicates the optimal number of buffers to be installed were 8 (eight), in order to get the design that does not exceed the allowable stress. Keywords: voltage, sustained loads, occasional loads, thermal expansion, standard ASME B31-3, buffer


Detil Peneliti

Dosen Pembimbing 1 :Dimas Endro Witjonarko
Dosen Pembimbing 2 : Nopem Ariwiyono

Program Studi : D4 - TEKNIK PERPIPAAN
Angkatan : 2009


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.