ANALISIS PENGARUH TEMPERATUR INJEKSI, TEKANAN HOLDING DAN WAKTU PENDINGINAN TERHADAP DIMENSI PADA PRODUK PEDAL SEPEDA MENGGUNAKAN METODE RESPON SURFACE.

ANALYSIS OF THE EFFECT OF INJECTION TEMPERATURE, PRESSURE HOLDING AND COOLING TIME FOR THE DIMENSIONS OF BICYCLE PEDAL PRODUCTS USING RESPONSE SURFACE METHOD.

Mukh. Haris Muzzaqi (6610040056)


Abstrak

Pada proses produksi menggunakan mesin injection moulding ini tidak terlepas beberapa masalah yaitu ukuran produk yang tidak sesuai dengan rencana awal. Desain cetakan yang kurang optimal dan pengaruh parameter proses injection moulding seperti temperatur injeksi, tekanan holding, dan waktu pendinginan dapat mempengaruhi timbulnya masalah tersebut. Akibatnya kualitas produk yang kita buat mengalami penurunan kualitas. Untuk mendapatkan parameter setting yang cocok diperlukan studi lapangan untuk mengetahui hubungan antara desain produk terhadap parameter proses, seperti temperatur injeksi, tekanan holding, dan waktu pendinginan. Setelah itu mengolah data hasil penelitian dengan menggunakan metode respon surface untuk mengetahui hubungan parameter proses yang tidak berpengaruh terhadap dimensi produk. Dari penelitian ini didapatkan bahwa temperatur injeksi, tekanan holding, dan waktu pendinginan berpengaruh terhadap dimensi pada produk pedal sepeda. Nilai optimum kombinasi parameter proses berturut-turut ialah temperatur injeksi (Tmelt)=227,76oC, tekanan holding (Phold)= 85,41 MPa, dan waktu pendinginan (tcold)= 156,62 detik dengan nilai respon yang lebih optimum dari respon awal. Dan dari penelitian ini pula didapatkan hubungan parameter proses terhadap keakuratan dimensi pada produk pedal sepeda dengan ditunjukan nilai optimum Ydimensi sebesar 19.84 mm.


Abstract

In the process of production using injection molding machine is not apart some of the problems that the size of the products which are not in accordance with the original plan. Less than optimal mold design and the influence of process parameters injection molding such as temperature injection, holding pressure and cooling time can affect the onset of the problem. As a result, the quality of the products that we make quality decreased. To obtain a suitable parameter settings required field study to determine the relationship between the product design process parameters, such as injection temperature, holding pressure and cooling time. After that process the research data using the response surface method to determine the relationship of process parameters that do not affect the dimensions of the product. From this study it was found that the temperature of injection, holding pressure and cooling time effect on the dimensions of the bicycle pedal products. The optimum value of the combination of process parameters are temperature successive injection (Tmelt) = 227,76oC, holding pressure (Phold) = 85.41 MPa, and cooling time (tcold) = 156.62 seconds with a more optimum response value of the initial response . And from this study also found a relationship to the process parameters on the dimensional accuracy of the bicycle pedal products shown Ydimensi optimum value of 19.84 mm.


Detil Peneliti

Dosen Pembimbing 1 :Rina Sandora
Dosen Pembimbing 2 : Bayu Wiro K

Program Studi : D4 - TEKNIK DESAIN DAN MANUFAKTUR
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.