PERANCANGAN FIRE INTEGRATED SYSTEM DI GEDUNG MEZZANINE DAN ANALISA MANFAAT BIAYA

design fire integrated system in the mezzanine building and benefit cost analysis

Himatul Mar'ati (6510040057)


Abstrak

PT. ABC merupakan perusahaan manufaktur internasional yang memproduksi boiler. perusahaan ini memiliki beberapa ruangan khusus salah satunya ruang dokumen (DMS) dan laboratorium. dikarenakan dalam ruangan tersebut terdapat rangkaian listrik dan berpotensi kebakaran yang menyebabkan kerusakan terhadap benda - benda berharga dan penting yang ada maka diperlukan perancangan sistem untuk menanggulangi kebakaran dan menminimalisir dampak kebakaran yang terjadi. Didalam ruangan tersebut belum tersedia sarana proteksi kebakaran. Tugas akhir ini terkait sebuah perancangan FM 200 (HFC 227ea) fire integrated system yang bersifat otomatis, mampu memadamkan kebakaran sendiri ketika mendapatkan sinyal kebakaran dari sebuah detektor dan sensor. Terdapat dua tipe dalam perancangan FM 200 (HFC 227ea) fire integrated system, yakni menggunakan sistem perpipaan dan thermatic auto sprinkler dan perancangan ini berdasarkan NFPA 2001. Dalam perancangan ini membutuhkan penganalisaan manfaat biaya melalui pendekatan benefit cost ratio. Pendekatan tersebut sebagai suatu langkah pengajuan kepada pihak menejemen dalam mengeluarkan anggaran untuk merancang FM 200 (HFC 227ea) fire integrated system. perancangan FM 200 (HFC 227ea) fire integrated system menggunakan pipa untuk ruangan dokumentasi dan laboratorium membutuhkan 451,94 kg FM 200, 2 buah (dua) nozzle spray, dan 5 buah (lima) smoke detector. Sedangkan untuk thermatic auto sprinkler dibutuhkan 28 FM 200 dengan kapasitas 5 kg. Thermatic auto sprinkler dijadikan sebagai pilihan alternatif terbaik karena memiliki investasi (annual cost) terbesar.


Abstract

-PT. ABC is an international manufacturing company producing boiler. This company have several special spaces, one of them is document space (DMS) and laboratory. Due to, there any electrical circuits in the space that have potential to fire causing damage on the existing valuable and important things, thus it needed system designing to overcome fire and minimize the impact of fire happened. It has not been available fire protection tools in the space. This last assignment related to a designing of FM-200 (HFC-227ea) Fire Integrated System with the characteristics of automatic, capable to extinguish fire by itself when get fire signal from a detector and sensor. There are two types in the designing of FM-200 (HFC-227ea) Fire Integrated System, that is, using piping system and Thermatic Auto Sprinkler and this designing was based on NFPA 2001. In this designing needed the analyzing of cost benefit by means of Benefit Cost Ratio approach. The approach was as a submission step to the management side in issuing budget for designing FM-200 (HFC-227ea) Fire Integrated. The designing of FM-200 (HFC-227ea) Fire Integrated System using pipe for document and laboratory spaces needed 451.94 kg of FM-200, two (2) nozzle sprays, and five (5) smoke detectors. While, for Thermatic Auto Sprinkler was needed 28 FM-200 tubes of capacity 5 kg. Thermatic Auto Sprinkler was made as the best alternative choice because it has the greatest value of investments (annual cost). Keywords: Benefit Cost ratio, FM-200 (HFC-227ea) Fire Integrated System, Thermatic Auto Sprinkler.


Detil Peneliti

Dosen Pembimbing 1 :Lukman Handoko
Dosen Pembimbing 2 : Wiediartini

Program Studi : D4 - TEKNIK KESELAMATAN DAN KESEHATAN KERJA
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.