STUDI PENGARUH FAKTOR ARAH ANGIN, KECEPATAN ANGIN, DAN KELEMBABAN UDARA DALAM DISPERSI EMISI PARTIKULAT (STUDI KASUS : PABRIK PELEBURAN BAJA PT.X)

STUDY ON THE EFFECT OF WIND DIRECTION, WIND SPEED AND HUMIDITY FACTORS IN PARTICULATE EMISION DISPERSION (CASE OF STUDY: STEEL FACTORY PT.X)

Denny Angriawan Nurcahya (6510040010)


Abstrak

ABSTRAK PT. X merupakan perusahaan yang bergerak di bidang manufaktur peleburan baja yang menghasilkan produk akhir berupa Round Bar (Billet) dan Wire Rod dengan kapasitas maksimal 80 ton. PT. X memiliki permasalahan higiene berkaitan dengan keluaran partikulat yang dihasilkan dari proses produksi atau proses peleburan baja yang mencemari area sekitar PT.X, khususnya area pemukiman penduduk. Tujuan dari penelitian ini adalah untuk mengetahui kualitas udara ambien dan jumlah partikulat di area sekitar PT.X yaitu di area pemukiman penduduk yang dekat dengan lokasi pabrik berdasarkan arah mata angin dominan, maupun arah angin non dominan. Pengambilan sampel di lakukan di 36 titik, setelah itu memetakan hasil pengukuran menggunakan software surfer X. Metode pengukuran kuantitas dari partikulat adalah menggunakan High Volume Air Sampler (HVAS) dengan pedoman SNI 19-7119.3-2005. Hasil dari penelitian ini di dapatkan, arah mata angin dominan pada tahun 2009 hingga 2013 adalah, pada tahun 2009 ke arah Timur (E) dengan kecepatan rata-rata 6,11667 Knots, tahun 2010 ke arah selatan/timur (S/E) dengan kecepatan angin rata ? rata 7,2 knots, tahun 2011 ke arah timur/tenggara (E/SE) dengan kecepatan angin rata ? rata 7,66667 knots, pada tahun 2012 kearah timur/selatan (E/S) dengan kecepatan angin rata ? rata 7,591667 knots, dan pada tahun 2013 ke arah timur/timur laut (E/NE) dengan kecepatan angin rata ? rata 7,616667 knots. Hasil pengukuran kuantitas partikulat pada area sekitar PT.X berdasarkan arah mata angin adalah berkisar antara 1,084 mg/m3 ? 3,475 mg/m3 dari semua lokasi titik sampel mulai dari lokasi titik sampel 1 sampai lokasi titik sampel ke 36 (diatas Baku Mutu yang ditetapkan). Hasil dari pemetaan Surfer X di dapatkan dispersi partikulat terbesar terdapat pada area barat dari sumber pencemar pada arah angin non dominan, keadaan ini dikarenakan terdapat pabrik peleburan baja lain di sekitar PT.X tepatnya berada di sebelah barat PT.X. Hasil perhitungan jumlah filter yang sudah di lakukan di dapatkan hasil yaitu sebanyak 352 buah, sedangkan filter yang telah terpasang pada dust collector sebanyak 320 buah filter. Rekomendasi pengendalian engineering control adalah dengan menambah 32 buah filter, untuk memaksimalkan kinerja dari dust collector. Kata Kunci: Roundbar (Billet), Wire Rod, Surfer X, High Volume Air Sampler, Filter, Partikulat, Engineering Control, Dust Collector


Abstract

ABSTRACT PT. X is a company engaged in manufacturing steel mills that produce the final product such as Round Bars (Billet) and Wire Rod with a maximum capacity of 80 tons. PT. X has hygiene problems associated with particulate output generated from the production process or the steel smelting process that pollutes the surrounding area PT.X, particularly the human settlements area. The purpose of of this research was to determine the ambient air quality and number of particulates in the surrounding area PT.X human settlements are in areas close to the plant site by the dominant wind direction, as well as non-dominant wind direction. Sampling was done at 36 points, after it mapped the measurement results using software surfer X. quantity of particulate measurement methods is using High Volume Air Sampler (HVAS) with SNI guidelines 19-7119.3-2005. The results be obtained from of this research, dominant wind direction in 2009 until 2013 was, in 2009 to the East (E) with an average speed of 6.11667 Knots, in 2010 to the south / east (S / E) with an average speed of 7.2 knots, in 2011 to the east / southeast (E / SE) with an average speed of - 7.66667 knots, in 2012 to the east / south (E / S) with an average speed of 7.591667 knots, and in 2013 to the east / northeast (E / NE) with an average speed of 7.616667 knots. The results of measurement of the quantity of particulates in the surrounding area PT.X based on the direction of the wind is ranged between 1.084 mg/m3 - 3.475 mg/m3 of all sample point locations ranging from the location of the sample point to the location of the sample point 1 to 36 (Quality Standards set out above) . The results of the mapping Surfer X in particulate dispersion biggest get there on the western area of the sources of pollution in non-dominant wind direction, this situation is because there are other steel smelters around PT.X precisely located on the west PT.X. The results of the calculation of the number of filters that have been done showed that as many as 352 pieces, while the filters that have been installed on as many as 320 pieces of dust collector filters. Recommendations of engineering control is to add 32 pieces of filter, to maximize the performance of the dust collector. Keywords: Roundbar (Billet), Wire Rod, Surfer X, High Volume Air Sampler, Filter, Particulate, Engineering Control, Dust Collector.


Detil Peneliti

Dosen Pembimbing 1 :Denny Dermawan
Dosen Pembimbing 2 : Indri Santiasih

Program Studi : D4 - TEKNIK KESELAMATAN DAN KESEHATAN KERJA
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.