Analisis bahaya listrik berdasarkan PUIL 2000 serta pengujian infrared thermography pada panel distribusi di PPNS (Politeknik Perkapalan Negeri Surabaya)

Electrical Hazard Analysis Base on PUIL 2000 and Infrared Thermography Testing on Distribution Panel of PPNS (Shipbuilding Institute of Polytechnic Surabaya

Nanda Ika Windiansih (6510040003)


Abstrak

Panel-panel listrik seperti SDP (Sub Distribution Panel) dan sub-sub panel lainnya adalah salah satu bagian dari instalasi listrik yang penting untuk ditinjau sistem keselamatannya. Kegagalan pada jaringan panel dapat mengakibatkan kebakaran yang dapat membahayakan keselamatan, dimana pernah terjadi kebakaran pada salah satu sub panel yang disuplai oleh SDP dari gedung perkuliahan. Penelitian ini menggunakan checklist sebagai alat bantu dalam melakukan inspeksi. Kemudian menggunakan what-if analysis untuk mengidentifikasi bahaya dan memberikan gambaran konsekuensi yang mungkin terjadi serta memberikan rekomendasi pada ketidaksesuaian terhadap PUIL 2000. Dari analisa yang dilakukan ditemukan ketidaksesuaian pada panel antara lain proteksi terhadap sentuh langsung yang kurang, tidak terdapatnya gawai proteksi arus sisa (GPAS), luas penampang penghantar proteksi tidak memenuhi syarat, tidak terdapat proteksi dari efek termal, penataan panel yang salah dan tidak tersedianya ruang pelayanan, tidak terdapat penandaan, tidak terdapat sakelar masuk, pembebanan yang berlebih, tidak terdapatnya kunci pada panel, tidak terdapat instrument ukur dan indikator, dan tidak terdapat komponen gawai kendali. Kondisi komponen setelah dilakukan penembakan infrared thermography di temukan overload, baut yang longgar, komponen tidak dapat memenuhi kinerjanya karena masing-masing komponen memiliki life time, dan terbakar. Rekomendasi yang diberikan yaitu berupa penggantian : Kabel MCB panel lantai 3, kabel MCB panel lab. Cadd III, terminal panel SDP, fuse panel SDP, kabel panel SDP, kontaktor panel bengkel reparasi dan bengkel mesin listrik, kabel MCB panel bengkel mesin listrik, MCB bengkel mesin listrik, MCB panel lantai 2, dan MCB lab. Cadd III,. Selain penggantian kabel, dapat dilakukan pemberian : mika penutup terminal sebagai rumah kabel, gawai kendali, sakelar masuk pada SDP, GPAS, penandaan dan bagan sirkit PHBK dan kunci panel. Rekomendasi lain yang dapat diberikan berupa penataan penempatan panel dan ruang pelayanan serta pemberian alat pelindung diri yang berupa safety shoes, safety goggles dan leather gloves. Kata Kunci : Sub Distribution Panel, checklist, what-if analysis, infrared thermography.


Abstract

Electrical panels such as SDP (Sub Distribution Panel) and other sub-panel is one part of the electrical installation are essential for safety systems is reviewed. Failure may result in the panel such as fire that may endanger the safety, where ever there is a fire in one of the sub-panels are supplied by the SDP from the lecture building. This study used the checklist as a tool in conducting inspections. Then using what-if analysis to identify hazards and provide an overview of the possible consequences and provide recommendations on noncompliance with PUIL 2000. An analysis found a discrepancy on the panel include protection against direct touch less, absence of residual current protective devices (GPAs), conductor cross-sectional area of protection do not qualify, there is no protection from thermal effects, the panel arrangement is wrong and not the availability of space services, there are no markings, there is no switch in, excessive loading, the absence of a key on the panel, there is no measuring instruments and indicators, and there is no control device components. Component condition after shooting infrared thermography found overload, loose bolts, components can not meet its performance because each component has a life time, and burning. The recommendations given in the form of replacement : MCB Cable panel on 3rd floor, wiring MCB panels on lab Cadd III, terminal SDP panels, fuse panels SDP, SDP panel wiring, contactor panel on repair shop and electric machinery workshop, MCB panel on wiring electrical workshop, MCB of electrical machinery workshop, MCB panel of the 2nd floor, and MCB on lab. Cadd III,. In addition to cable replacement, can be performed giving : mica cover as home wiring terminals, control device, switch on the incoming SDP, GPAs, tagging and CBHE circuit diagram and key panels. Another recommendation that can be given a placement arrangement of panels and room service as well as the provision of personal protective equipment such as safety shoes, safety goggles, and leather gloves. Keyword : Sub Distribution Panel, checklist, what-if analysis, infrared thermography.


Detil Peneliti

Dosen Pembimbing 1 :Hendro Agus Widodo
Dosen Pembimbing 2 : Rona Riantini

Program Studi : D4 - TEKNIK KESELAMATAN DAN KESEHATAN KERJA
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.