PERENCANAAN SISTEM PENGKONDISIAN UDARA EXTENSION CONTROL ROOM CCM (STUDI KASUS DI PT. X)

DESIGN OF AIR CONDITIONING SYSTEM AT EXTENSION CONTROL ROOM CCM (CASE STUDY AT PT. X)

Alfi Torich (6509040061)


Abstrak

ABSTRAK PT. X merupakan perusahaan yang bergerak dibidang manufaktur berupa peleburan baja yang menghasilkan produk bernama wirerod. Wirerod dihasilkan melalui proses peleburan sponge dan besi tua dengan menggunakan Electric Arc Furnace (EAF), setelah itu dilanjutkan ke Ladle Reheating Furnace (LRF) dan kemudian di Continous Casting Machine (CCM). Di area ini terjadi pencetakan billet dan terdapat ruangan yang baru dibangun yaitu Extension Control Room Hasil pengukuran yang pernah dilakukan sebelumnya di area ini didapatkan nilai suhu kering sebesar 34,3 oC dan kelembaban relatif 71 % Kondisi ini melebihi NAB yang dipersyaratkan di suhu kering 25,80C ? 27,10C dan kelembaban relatif yaitu 40% - 50% (SNI 03-6572-2001). Tujuan penelitian ini adalah mengevaluasi kondisi suhu kering dan kelembaban relatif, agar pekerja dalam keadaan yang nyaman dan terhindar dari PAK (Penyakit Akibat Kerja), serta terhindar dari penurunan produktivitas kerja. Tahap pertama untuk melakukan pengkondisian udara yaitu menghitung beban pendinginan ruangan yang diakibatkan sumber panas dari dalam dan dari luar. Tahap kedua dilakukan perhitungan udara suplai dan daya evaporator. Tahap terakhir adalah perencanaan pengkondisian udara. Hasil pengukuran langsung didapatkan nilai suhu kering sebesar 36,87 oC, dan kelembaban relatif 53 % (melebihi NAB). Untuk menurunkan suhu kering menjadi 26 oC dan kelembaban relatif menjadi 45%, melalui perhitungan didapatkan beban pendinginan sebesar 7.817,96 Watt dengan udara suplai 912,323 CFM, serta safety factor 5%. Berdasarkan katalog produk mesin pengkondisian udara merk Fujitsu, diperoleh kapasitas pendingan sebesar 7,9 kw, dimensi bagian dalam (indoor unit) 320 ? 1120 ? 220 mm dan dimensi bagian luar (outdoor unit) 900 ? 900 ? 350 mm. Peletakan mesin pengkondisian udara indoor dengan tinggi 3,4 m, tidak menghadap orang secara langsung dan tidak menghadap ke pintu. Untuk outdoor ditempatkan di tempat yang mudah dijangkau untuk perawatan. Kata kunci : Suhu Kering, Kelembaban Relatif, Pengkondisian udara ?


Abstract

ABSTRACT PT. X is a company engaged in manufacturing a steel foundries that produce products named wirerod. Wirerod generated through the process of melting sponge and scrap metal by using Electric Arc Furnace (EAF), after that proceed to the Ladle Reheating Furnace (LRF) and then in Continuous Casting Machine (CCM). This happened in the area of printing billet and there is room newly built Control Room Extension of measurement results that have been done before in this area value obtained dry temperature of 34.3 ? C and 71% relative humidity conditions exceed the required NAB in dry temperature 25, 80C - 27.10 C and a relative humidity of 40% - 50% (SNI 03-6572-2001). The purpose of this study is to evaluate the dry conditions of temperature and relative humidity, so that workers in comfortable circumstances and avoid PAK (Occupational Diseases) and avoid the decline in labor productivity. The first stage is to calculate the air conditioning cooling load caused by indoor heat sources from within and from outside. A second phase of the supply air and power calculations evaporator. The last stage is the planning of the air conditioning. The results of direct measurements are dry temperature value of 36.87 ? C and relative humidity of 53% (exceeding NAB). To decrease the dry temperature to 26 ? C and the relative humidity to 45%, through the calculation of the cooling load 7.817,96 Watts, supply air 912.323 CFM and 5% safety factor. Based on product catalog of Fujitsu air conditioning machines found that cooling capacity 7.9 Kw, indoor unit dimension 320 ? 1120 ? 220 mm and outdoor unit dimension 900 ? 900 ? 350 mm. With the laying of the indoor air conditioning machines at height of 3.4 m, not facing people directly and not facing the door. For outdoor, it is placed in an easily accessible for maintenance. Key Word: Dry Temperature, Relative Humidity, Air Conditioning.


Detil Peneliti

Dosen Pembimbing 1 :Denny Dermawan
Dosen Pembimbing 2 : Mirna Apriani

Program Studi : D4 - TEKNIK KESELAMATAN DAN KESEHATAN KERJA
Angkatan : 2009


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.