PERANCANGAN DAN SIMULASI AUTOMATIC DELUGE SYSTEM DENGAN HEAD SPRINKLER UNTUK MENGURANGI RISIKO KEGAGALAN

DESIGN AND SIMULATION OF AUTOMATIC DELUGE SYSTEM WITH HEAD SPRINKLER TO REDUCE THE RISK OF FAILURE

Mades Darul Khairansyah (6509040025)


Abstrak

PT. Trans Pasific Petrochemical Indotama (PT.TPPI) merupakan industri petrokimia yang mengolah hydrocarbon dalam kapasitas produksi skala besar. Kapasitas bahan baku berupa condensate mencapai 101.000 BPSD. Tahapan awal untuk menghasilkan produk hydrocarbon adalah prefractionation. Prefractionation adalah pemisahan dua komponen atau lebih di dalam campuran yang mempunyai beda titik didih berjauhan yang terdapat pada prefractionation unit. Salah satu produk yang merupakan fraksi terberat dari proses ini adalah Residue atau Blended Fuel Oil (BFO). Produk ini berasal dari Distillate Column 201-C-004 bottom, di pompa oleh Distillate Column Bottom Pump 201-P-007A/B dengan temperatur rata-rata sebesar 335 ?C. Automatic deluge system digunakan untuk memproteksi pompa tersebut dari bahaya kebakaran. Automatic deluge system yang digunakan mengacu SNI 03-3985-2000 untuk menentukan jenis head sprinkler yang digunakan. Selain itu, NFPA 13 digunakan dalam menentukan perlengkapan apa saja yang diperlukan dalam merancang deluge system. Dari tahap perhitungan didapatkan penurunan nilai risiko kegagalan sebesar 4,2593507%, dengan penambahan 1 buah pemicu dengan jenis bulp berwarna merah, sedangkan untuk perhitungan sprinkler didapatkan hasil bahwa jumlah sprinkler yang dibutuhkan adalah 2 buah. Deluge valve yang digunakan adalah sebesar 2?. Kapasitas daya pompa adalah sebesar 14,03 HP sedangkan yang tersedia adalah 24 HP. Kebutuhan air sebesar 19 m?. Kata kunci : automatic deluge system, daya pompa, deluge valve, head sprinkler.


Abstract

PT. Trans Pasific Petrochemical Indotama (PT.TPPI) is a petrochemical industry that processing hydrocarbon in a large scale. Condesate's capacity as raw material has reached 101.000 BPSD. First step to produce hydrocarbon is prefractionation. Prefractionation is a process that separating two or more component in a mixture which have different boiling point on prefactionation unit. One of the product that having the heaviest fraction on this process is residue or blended fuel oil (BFO). This product come from distillate column 201-C-004 bottom and be pumped by distillate column bottom pump 201-P-007A/B on average temperature of 335 ?C. Automatic deluge system use to protect pump from explotion hazard. Automatic deluge system that has been used refer to SNI 03-3985-2000 to determine the variety of appropriate head sprinkler. In addition, this research also use NFPA 13 as the reference to determine other equipment that needed to design deluge system. Based on the calculation there are 4,2593507% decrease of failure rate, eith desaign are 1 piece of red bulp sprinkler, while for sprinkler calculation, it conclude that the number of sprinkler needed are two pieces. Deluge valve that being used is 2 inch. The pump capacity is 14,03 HP while the existing is 24 HP, and also the water needed is 19 m?. Keywords : pump capacity, head sprinkler, deluge valve, automatic deluge system.


Detil Peneliti

Dosen Pembimbing 1 :Priyo Agus Setiawan
Dosen Pembimbing 2 : Moch Luqman Ashari

Program Studi : D4 - TEKNIK KESELAMATAN DAN KESEHATAN KERJA
Angkatan : 2009


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.