ANALISA RISIKO FENOMENA BOILING LIQUID EXPANDING VAPOR EXPLOSION (BLEVE) DI TANGKI 1-BUTENE PT. X

RISK ANALYSIS OF BOILING LIQUID EXPANDING VAPOR EXPLOSION (BLEVE) PHENOMENA AT 1-BUTENE TANK PT. X

Fresty Fizzaria (6509040010)


Abstrak

Pada bulan Januari 2013, PT. X melakukan loading 1-Butene (flammable liquid) untuk pertama kalinya. Liquid ini kemudian disimpan dalam tangki bola. Dengan adanya penambahan bahan ini, potensi bahaya yang ada di perusahaan ini semakin besar. Dalam hal ini, potensi catastrophes yang dibawa oleh cairan mudah terbakar di dalam suatu bejana bertekanan adalah BLEVE (Boiling Liquid Expansion Vapor Explosion). Penelitian ini menggunakan metode FTA (Fault Tree Analysis) untuk mengetahui basic cause dan kemungkinan skenario dari BLEVE. Berdasarkan skenario tersebut, dilakukan perhitungan risiko BLEVE dengan mengacu pada NFPA 59A dan hanya memperhitungkan number of injury sebagai konsekuensinya. Setelah mengetahui besarnya risiko, validasi kecukupan protection layer dalam mencegah terjadinya BLEVE dilakukan dengan menggunakan LOPA (Layer of Protection Analysis). Setelah dilakukan validasi menggunakan LOPA, diperoleh bahwa protection layer tangki 1-Butene di PT.X terhadap BLEVE sudah mencukupi. Hal ini didapatkan dari berkurangnya frekuensi basic/initiating event setelah dibangun LOPA dari 0.262 menjadi 0.0355 kali per tahun. Kata kunci: BLEVE, FTA, LOPA


Abstract

January 2013, PT. X was loading 1-Butene (flammable liquid) for the first time ever. This liquid is placed in sphere tank. Because of this additional liquid placed, potential risk of hazard is getting higher than before. One of its catastrophes potential from this flammable liquid inside of pressure vessel is BLEVE (Boiling Liquid Expansion Vapor Explosion). In its development, this research uses FTA (Fault Tree Analysis) for decide the basic cause and probability of BLEVE scenario. Based on that scenario, risk will be calculated. The calculation of this risk will be based on NFPA 59A which it only considers number of injury as its consequence. Then, validation of protection layer reability needed to make sure that it can prevent BLEVE. This validation uses LOPA (Layer of Protection Analysis). From validation based on LOPA, protection layer at 1-Butene sphere tank is good enough to prevent BLEVE. It is proof on number of basic/initiating event frequency is decreased after LOPA contruction from 0.262 to 0.0355 per year. Keywords: BLEVE, FTA, LOPA


Detil Peneliti

Dosen Pembimbing 1 :Arief Subekti
Dosen Pembimbing 2 : Mohamad Hakam

Program Studi : D4 - TEKNIK KESELAMATAN DAN KESEHATAN KERJA
Angkatan : 2009


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.