ANALISIS GROUNDING TRANSFORMATOR 22TR300 PADA UNIT PRODUKSI PHONSKA IV PABRIK II PT. PETROKIMIA GRESIK

ANALYSIS OF GROUNDING TRANSFORMER 22TR300 AT PHONSKA FACTORY IV PRODUCTION UNIT II PT. PETROKIMIA GRESIK

Risko Holen Andrianto (6413030051)


Abstrak

ABSTRAK Sistem tenaga listrik dituntut kehandalannya setinggi mungkin dengan meminimalisir kemungkinan terjadinya gangguan, salah satunya adalah sistem pentanahan/groundingnya. Sistem grounding pada Transformator 22TR300 di Unit Produksi Phonska IV titik netralnya memakai sistem solid atau diketanahkan secara langsung. Namun jika transformator sebesar itu jika mengalami arus grounding ke tanah maka akan terjadi tegangan langkah disekitar transformator tersebut. Maka dari itu, sistem pentanahan netralnya harus diberi resistans. Sistem pentanahan netral melalui resistans ini yang dimaksud adalah sebelum titik netral transformator ditanam di tanah, atau titik netral dengan tanah diberi resistans atau tahanan. Besar tahanan dalam SPLN 26:1980 telah ditetapkan untuk tahanan rendah 12 Ohm untuk jaringan kabel tanah, tahanan rendah 40 Ohm untuk saluran udara dan kabel tanah, tahanan tinggi untuk saluran udara. Didalam sistem pentanahan juga harus diperhatikan bagaimana menentukan elektroda bumi dan pemasangannya. Sistem grounding pada Transformator 22TR300 menggunakan sistem solid. Menurut standar, sistem grounding pada Transformator 22TR300 harus diketanahkan melalui resistans dengan besar resistans 12 Ohm. Elektroda yang terpasang adalah elektroda batang dengan bahan baja belapis tembaga yang berdiameter 15 mm, lapisan tembaga 2,5 mm dan berjumlah 2 buah elektroda batang masing-masing panjangnya 5 meter dengan penanaman elektroda batang ini ditanam secara dalam yaitu lebih dari satu meter. Menurut standar pemasangan elektroda bumi, pemasangan pada elektroda pentanahan Transformator 22TR300 tersebut sudah memenuhi standar yang menghasilkan nilai tahanan pentanahan dibawah 5 Ohm yaitu 0,595 Ohm. Kata kunci : Grounding, Transformator, Solid, Elektroda dan Resistans


Abstract

ABSTRACT Power system reliability demanded high as possible by minimizing the possibility of disturbances, one of which is a grounding system. The Transformer 22TR300 grounding system at Production Unit IV Phonska neutral point system using solid or directly grounded. However, if the transformer for it if you have to ground the grounding currents will occur around the transformer step voltage. Therefore, the neutral grounding system must be resistance. The system neutral grounding through the resistance of this question is before the neutral point of the transformer is planted in the ground, or the neutral point to the ground by the resistance or detention. Detainees in SPLN 26: 1980 has been set for lower custody for 12 Ohm cable network ground, low arrest 40 Ohm for air and land cable channels, high detainees to air channels. In the grounding system should also be considered how to determine earth electrode and installation. Grounding system in Transformer 22TR300 using solid system. According to the standard, grounding system in Transformer 22TR300 should grounded through great resistance with the resistance of 12 Ohm. Electrodes attached to the rod electrode material is steel belapis copper diameter of 15 mm, 2.5 mm and a copper layer amounted to 2 pieces of each electrode rod length of 5 meters with the planting of this rod electrodes planted in which more than one meter. According to the standard installation of earth electrodes, mounting the grounding electrode Transformer 22TR300 is already a standard that produces the grounding resistance values below 5 Ohm is 0.595 Ohm. Keywords: Grounding, Transformers, Solid, Electrodes and Resistance


Detil Peneliti

Dosen Pembimbing 1 :Achmad Syahid
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2013


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.