STUDI PERENCANAAN KAPASITAS EMERGENCY GENERATOR SET UNTUK MENYUPLAI BEBAN DI GADUNG BARU PADA PT.YANAPRIMA HASTAPERSADA TBK.

A STUDY OF PLANNING OF EMERGENCY CAPACITY OF GENERATOR SET TO SUPPLY THE LOADS IN THE NEW BUILDING AT PT.YANAPRIMA HASATAPERSADA TBK.

Luvi Setyorini (6413030038)


Abstrak

PT. Yanaprima Hastapersada merupakan sebuah perusahaan yang bergerak di bidang produksi tenun plastik. Proses produksi dilakukan secara terus-menerus selama 24 jam setiap hari. Perusahaan tersebut mendapat pasokan listrik dari PLN untuk memenuhi seluruh kebutuhan listrik dengan menggunakan lima transformator. Kelima transformator tersebut digunakan untuk menyuplai beban-beban yaitu beban penerangan dan mesin produksi. Beban-beban tersebut terletak pada tempat yang berbeda. Beban yang disuplai transformator I, transformator II dan transformator III terletak di gedung lama perusahaan; beban yang disuplai transformator IV dan transformator V terletak di gedung baru perusahaan. Mesin produksi yang disuplai oleh transformator IV lebih sering digunakan daripada mesin lainnya, sehingga transformator tersebut memiliki peranan penting untuk menunjang proses produksi. Kegiatan proses produksi akan terhenti apabila terjadi pemadaman listrik, dikarenakan tidak adanya suplai listrik cadangan pada gedung tersebut. Penerangan dan mesin produksi memiliki peranan penting dalam kegiatan proses produksi. Oleh karena itu, diperlukan perencanaan generator set. Generator set ini direncanakan untuk menyuplai beban-beban di transformator empat yang terletak di gedung baru perusahaan. Pada penelitian ini menggunakan metode pengukuran beban maksimum. beban maksimum diukur di panel LVMDP transformator IV. Hasil beban maksimum akan dibandingkan dengan beban terpasang untuk perencanaan kapasitas generator set. Hasil pengukuran beban terpakai di PT. Yanaprima Hastapersada saat beban maksimum adalah sebesar 822,724 kVA dan beban terpasang sebesar 942,292 kVA. Perencanaan genset ini menggunakan daya sebesar 1000 kVA yang telah disesuaikan dengan rating genset. Daya genset besarnya tidak sama dengan daya transformator, dikarenakan untuk efesiensi biaya. Perencanaan daya genset dengan menggunakan pengukuran beban maksimum ternyata dapat menyuplai total beban terpasang, sehingga beban terpasang dapat terpenuhi. Pengaman genset dalam perencanaan ini menggunakan MCCB 1600 A untuk melindungi genset apabila terjadi arus lebih dan hubung singkat. Luas penampang penghantar dalam perencanaan ini menggunakan jenis kabel NYY 3 (1 x 240 mm2). Kata kunci: Beban maksimum, Emergency generator set, Kabel NYY, Kapasitas genset, MCCB, Transformator IV.


Abstract

PT. Yanaprima Hastapersada is a company in the field of woven plastic production. The process of the production is done continuously for 24 hours every day. The company gets the electrical supply from the National Electricity Company to fulfill all the electricity needs by using five transformers. All of the transformers are used to supply lighting and production machine. Both of them are located at different places. The load which is supplied by transformer I, transformer II and transformer III is located in the company?s old building; the load which is supplied by transformer IV and transformer V is located in the company?s new building. The production machine which is supplied by transformer IV is used more frequently than other machines. Therefore, the transformer has an important role to support the process of production. The process of production stopped if the power failure, it is because there is no backup of electrical supply in the building. Lighting and production machine have an important role in the process of production. Therefore, the generator set planning is required. The generator set is going to be used to supply the loads in transformer IV located in the company?s new building. This research used measurement of maximum load method. The maximum load was measured at LVMDP transformer IV panel. The result of the maximum load compared with installed loads as determination of generator set capacity. The Result a planning of emergency capacity generator set uses measurements of maximum load. The loads used in PT. Yanaprima Hastapersada when maximum load is 822.724 kVA with total installed load of 942.292 kVA. The planning of generator set uses 1000 kVA with has been adapted to the genset rating. The great power of the genset is not the same as the power of transformer, it is because of the cost effeciency. The planning of generator set power which uses measurement load of maximum load can supply a total of the load installed, so it can be fulfilled. The safety of the genset in this plan uses 1600 A of MCCB to protect the genset while over current and sort circuit. The sectional are of conductor this plant uses NYY 3(1 x240 mm2) cable type. Keyword: Maximum load, Emergency generator set, NYY cable, Genset capacity, MCCB, Transformer IV.


Detil Peneliti

Dosen Pembimbing 1 :Urip Mudjiono
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2013


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.