Analisis Sistem Safety Device Pada Main Switch Board Kapal Coaster 1200 GT

ANALYSIS SYSTEM SAFETY DEVICE MAIN SWITCH BOARD ON SHIPS COASTER 1200 GT

Satria Okta Umara (6413030032)


Abstrak

Dewasa ini sistem safety device Main Switch Board pada kapal menjadi salah satu faktor penunjang demi keselamatan maritime dalam berlayar. kompetensi ini sangat penting dalam rangka menjaga sistem distrbusi kelistrikan kapal tetap tersuplai dengan kebutuhan yang ada. Sehubungan hal tersebut maka untuk mengoptimalkan fungsi kapal, harus di dukung berbagai sarana kelengkapan di atas kapal. Demi mempermudah dan kenyamanan dalam melakukan kegiatan di laut. Salah satu faktor yang dapat menunjang hal tersebut adalah perencanaan instalasi listrik di atas kapal atau sistem distribusi di atas kapal. Untuk sistem safety device di kapal harus di sesuaiakan dengan standart yang telah di tentukan Biro Klasifikasi Indonesia mengingat sistem safety device berperan penting pada kelistrikan di kapal dan perlu di perhatikan juga untuk oprasionalnya karena berkaitan dengan keselamatan jiwa. Maka dari itu safety device perlu di lakukan pengujian untuk mengetahui apakah komponen safety device telah sesuai dengan spesifikasi dan satandart yang ada. Dengan studi penelitian, observasi lapangan, analisis data maka hasil dari pembahasan adalah, setting inject arus untuk Prefential Trip sebasar 100% dan mempunyai delay time rata-rata 10,52 detik. Over current trip mempunyai nilai setting inject arus sebesar 110% dan harus mempunyai delay time tidak boleh melebihi 2 menit. Dari pengujian yang telah di lakukakn nilai rata-rata delay time Over Current Trip adalah 20,5 detik. Short Circut Trip mempunyai nilai setting inject arus sebesar 250%, dan harus mempunyai delay time yang singkat (hingga 500 ms). Dari hasil pengujian yang telah di lakukan nilai rata-rata delay time Short Circuit adalah 0,25 detik. Reverse Power Trip setting inject arus yang di gunakan adalah 10% dan harus mempunyai delay time 2-5 detik. Dari pengujian yang telah di lakukan nilai rata-rata delay time revere power trip adalah 4,96 detik. Under Voltage Trip nilai penurunan tegangan dari 70 % - 35%. Dan harus mempunyai delay time yang singkat sama dengan short circuit (500 ms). Dari pengujian yang telah di lakukan nilai rata-rata delay time Reverse Power Trip adalah 0,34 detik.


Abstract

Nowadays, Main Switch Board, the system safety devices on the ship becomes an enabling factor for the safety of maritime sailing. This competency is important in order to maintain the distribution electrical system of ship remains well supplied existing needs. Related to that matter, to optimize the function of the ship, then it must be supported various means of fittings on the boat in order to facilitate and comfort in performing activities in the sea. One of the factors that can support those is good installation planning of electricity on board or distribution system on board. The system safety device on the ship should be appropriate with a standard that has been set by the Indonesian Classification considering safety system plays an important role in the electrical device on board and also needs more attention for its operational because it relates to the salvation of people. Thus the safety device needs to do a test to determine whether the components of safety devices appropriate with the specifications and standard there. With research studies, field observations, data analysis, the results of the discussion are the current setting of inject for Prefential Trip is 100% and has an average delay time 10.52 seconds. Over current trip has value inject current setting of 110% and must have a time delay should not exceed 2 minutes. From the testing that has been done; found that the average rating Over Current Trip delay time is 20.5 seconds. Short circuit Trip inject current setting has a value of 250%, and should have a short time delay (up to 500 ms). From the testing that has been done in the average value of Short Circuit delay time is 0.25 seconds. Reverse Power Trip inject current settings used is 10% and should have a delay time of 2-5 seconds. From the testing that has been done the average value revere power trip delay time is 4.96 seconds. Under Voltage Trip value of the voltage drop of 70% - 35%. And should have a short delay time is equal to short circuit (500 ms). From the testing that has been done, the average value of Reverse Power Trip delay time was 0.34 seconds.


Detil Peneliti

Dosen Pembimbing 1 :Hendro Agus Widodo
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2013


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.