ANALISA PERBAIKAN FAKTOR DAYA PADA PANEL LV 0,4 KV MENGGUNAKAN KAPASITOR BANK 300 KVAR DI PT.X

ANALYSIS OF POWER FACTOR IMPROVEMENT ON THE 0.4 KV LV PANEL WITH CAPACITOR BANK 300 KVAR USE IN PT.X

Mukhlis Ahmadi Heksa (6412030013)


Abstrak

Perbaikan faktor daya sangat di butuhkan di Industri, karena industri merupakan konsumen daya listrik yang cukup besar. Sebagian besar beban listrik di industri bersifat induktif, misalnya motor listrik. Akibatnya faktor daya (cos phi) nya rendah. Faktor daya yang buruk dengan nilai faktor daya dibawah 0,85 akan menimbulkan konsumsi daya reaktif yang besar. Penggunaan daya reaktif ini akan di kenakan biaya/denda dari PLN jika nilai faktor daya nya dibawah 0,85, sesuai standar yang telah di tetapkan oleh PT. PLN (PERSERO). Perbaikan rendahnya faktor daya dapat di lakukan dengan pemasangan kapasitor bank. Dimana alat ini berfungsi sebagai sumber daya reaktif untuk meningkatkan faktor daya, dengan cara mengkompensasi beban-beban induktif. Setelah melakukan analisa, didapatkan pemahaman tentang perhitungan daya reaktif yang dibutuhkan pada panel Low Voltage (LV) 0,4 KV, serta perhitungan kapasitas kapasitor bank, dengan cara teoritis serta pengambilan data. Hal ini dilakukan dalam upaya memenuhi ketentuan Peraturan Menteri Energi Dan Sumber Daya Mineral (ESDM) Republik Indonesia Nomor 31 Tahun 2014 tentang Tarif Tenaga Listrik yang disediakan Oleh Perusahaan Perseroan (PERSERO) PT Perusahaan Listrik Negara. Kata kunci: faktor daya, reaktif, kapasitor bank


Abstract

Power factor improvement is needed in industry, because the industry is consumer of quite large power. Most of the electrical load in industry is inductive, such as an electric motor. As a result, power factor (cos phi) is low. Poor power factor with power factor below 0.85 will cause a large consumption of reactive power. The use of reactive power will be charged by PLN if the value of the power factor is below 0.85, according to the standard that has been set by PT. PLN (Persero). The improvement of the low power factor can be done with the installation of capacitor banks. It works as a source of reactive power to improve power factor, by compensating inductive loads. After doing the analysis, an understanding about the calculation of the required reactive power on the panel Low Voltage (LV) 0.4 KV is obtained, and also the calculation capacity of the capacitor bank, theoretically as well as by data retrieval. This is done in order to comply with the Regulation of the Minister of Energy and Mineral Resources (ESDM) of the Republic of Indonesia Number 31 Year 2014 about Electricity Rates supplied by the Company (Persero) PT PLN. Key Word: power factor, reactive, capacitor banks


Detil Peneliti

Dosen Pembimbing 1 :Sryang Tera Sarena
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2012


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.