Studi Kelayakan Minyak Transformator pada Transformator HVPS (High Voltage Power Supply) 140 KW berdasarkan DGA (Dissolved Gas Analysis)

Feasibility Study on Transformer Oil on Transformer HVPS (High Voltage Power Supply) 140 KW by DGA (Dissolved Gas Analysis)

Seda Nor Aisyah (6411030059)


Abstrak

Transformator memiliki salah satu komponen penting yaitu minyak transformator, karena fungsinya selain sebagai isolator yang memberikan fungsi isolasi antar belitan dalam transformator, juga sebagai media pendingin untuk menyerap panas dari inti transformator dan belitan transformator. Kegagalan isolasi minyak pada transformator akan mengakibatkan gangguan yang signifikan bisa menghentikan proses produksi. Kandungan gas yang terlarut dalam minyak transformator secara tidak langsung menunjukkan kondisi itu sendiri. Oleh karena itu analisa terhadap minyak transformator atau Dissolved Gas Analysis (DGA) perlu dilakukan paling tidak satu kali dalam satu tahun dengan menggunakan tiga metode interpretasi DGA yaitu TDCG, Key Gas, dan Roger Ratio. Agar dapat mendeteksi dini akan adanya fenomena kegagalan pada transformator. Dengan dilakukannya pengujian DGA pada transformator, maka nilai yang didapat dari hasil pengujian tersebut diharapkan masih berada didalam batas toleransi yang diijinkan sesuai dengan standard IEC 60422-2005,sehingga nilai tersebut mampu mengindikasikan kualitas dari oli transformator HVPS (High Voltage Power Supply) kata kunci : Minyak Transformator,DGA,TDCG,Key Gas,Roger,Gas Chromatograph


Abstract

Transformer has one of the important components of transformer oil, because it functions as an insulator that provides the function of isolation between the windings in the transformer, as well as a coolant to absorb heat from the transformer core and transformer winding. The failure of the transformer insulating oil will result in a significant disruption could halt production process. The content of dissolved gases in the transformer oil implies the condition itself. Therefore, analysis of transformer oil or Dissolved Gas Analysis (DGA) needs to be done at least once a year by using the three methods of interpretation of DGA is TDCG, Gas Key, and Roger Ratio. In order to detect the existence of the phenomenon of premature failure of the transformer. By DGA tests were performed on the transformer, then the value obtained from the test results are expected to still be within the allowable tolerance limits according to IEC 60422-2005, so that the value is able to indicate the quality of the transformer oil HVPS (High Voltage Power Supply) keywords: transformer oil, DGA, TDCG, Gas Key, Roger, Gas Chromatograph


Detil Peneliti

Dosen Pembimbing 1 :Annas Singgih Setiyoko
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2011


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.