PENCEGAHAN TERJADINYA CURRENT UNBALANCE DI EMERGENCY GENERATOR PADA KRI SAMPARI TYPE KCR 60M PT.PAL INDONESIA (PERSERO), SURABAYA

PREVENTION OF CURRENT UNBALANCE IN THE EMERGENCY GENERATOR AT KRI SAMPARI TYPE KCR 60M AT. PAL INDONESIA (Persero), SURABAYA

El Nusa Putra Pratama (6411030053)


Abstrak

ABSTRAK PENCEGAHAN TERJADINYA CURRENT UNBALANCE DI EMERGENCY GENERATOR PADA KRI SAMPARI TYPE KCR 60M DI PT.PAL INDONESIA (PERSERO), SURABAYA Oleh : El Nusa Putra Pratama NRP: 6411030053 Emergency Generator adalah sumber tenaga listrik darurat / bantu untuk mensuplai daya listrik ke semua bagian kapal yang tidak beroprasi akibat Main Generator mengalami kegagalan atau kerusakan pada sistem kelistrikannya (blackout). Apabila blackout terjadi pada kapal, maka harus disiapkan sebuah sistem kelistrikan yang mampu memasok listrik ke peralatan ? peralatan krusial pada kapal. Untuk meningkatkan nilai keselamatan, sistem ini dibuat otomatis agar kapal tidak berada dalam keadaan blackout dalam waktu yang lama Pembagian beban emergency generator harus merata antar penghantarnya baik R, S dan T agar tidak terjadi current unbalance yang dapat menyebabkan netral pada feeder 220V bertegangan sehingga tidak dapat membentuk sudut listrik sempurna 120? dan menyebabkan kerugian atau losses. Metode analisis current unbalance ini dengan cara melakukan load test secara langsung, memberikan beban secara bertahap mulai dari 25%, 50%, 75% dan 100% sehingga dapat diketahui kinerja sistem kelistrikan emergency pada kapal tersebut. Kata Kunci : Emergency Generator, ESB (Emergency Switch Board), Ketidakseimbangan beban, Blackout


Abstract

ABSTRACT PREVENTION OF OCCURRENCE UNBALANCE INTERRUPTION IN THE EMERGENCY GENERATOR AT KRI SAMPARI TYPE KCR 60M AT. PAL INDONESIA (Persero), SURABAYA By: El Nusa Putra Pratama NRP: 6411030053 Emergency Generator is a source of emergency power / auxiliary power to supply electricity to all parts of the ship that are not in operation due to the Main Generator failure or damage to the electrical system (blackout). If a blackout occurs on the ship, then be prepared an electrical system that is capable of supplying power to the equipment - equipment crucial to the ship. To increase the value of safety, the system is made automatically so that the ship is not in a state of blackout in a long time. Distribution of emergency generator loads should be evenly distributed between both phases R, S and T in order to avoid current unbalance can cause the feeder neutral voltage 220V and so can not form a perfect electrical angle of 120 ? and cause harm or losses. This unbalance current analysis methods by means of direct load test, giving the load gradually starting from 25%, 50%, 75% and 100% so as to know the performance of the emergency electrical system on the ship. Key word: Emergency Generator, ESB (Emergency Switch Board), load unbalance, Blackout


Detil Peneliti

Dosen Pembimbing 1 :Isa Rachman
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2011


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.