ANALISA SISTEM EMERGENCY/DARURAT KELISTRIKAN PADA KMP SABUK NUSANTARA 200 DWT DI PT. F1 PERKASA

ANALYSIS OF ELECTRICAL EMERGENCY SYSTEM ON KMP SABUK NUSANTARA SHIP AT PT F1 PERKASA

Elton Kristian Silalahi (6411030026)


Abstrak

ANALISA SISTEM EMERGENCY/DARURAT KELISTRIKAN PADA KAPAL KMP SABUK NUSANTARA DI PT F1 PERKASA Sistem emergency/darurat kelistrikan pada kapal merupakan bagian yang sangat penting dalam operasional kapal. Perancangan sistem emergency/darurat listrik yang tepat dapat memberikan keamanan dan keselamatan kepada kapal dan seluruh isinya yang signifikan dalam operasionalnya saat terjadi kondisi black out di kapal. Kondisi Black Out adalah kondisi dimana sumber tenaga penggerak utama, permesinan bantu, dan peralatan lainnya pada kapal tidak beroperasi karena tidak adanya pasokan listrik yang disebabkan oleh kegagalan pada sistem kelistrikan. Maka sangat diperluakan penelitian utnuk mengatasi masalah ini. Dalam tugas akhir ini difokuskan pada penelitian peralatan yang digunakan saat terjadi emergency kelistrikan pada kapal KMP Sabuk Nusantara, penelitian besarnya daya listrik yang dibutuhkan saat terjadi emergency, system pengaktifan emergency generator dan baterai 24 DC Volt, penelitian komponen yang ditambahkan untuk mendukung system otomatisasi emergency generator, penelitian hubungan pengaman dan luas penampang kabel terhada system emergency, dan pembuatan simulasi system emergency generator . Semua penelitian ditentukan dengan standart BKI (Biro Klasifikasi Indonesia). Untuk mendapatkan hasil dengan metode analisis dilakukan dengan menganalisis data sekunder dari hasil observasi. Peralatan yang menyala saat terjadi emergency pada kapal hanya memnuhi 50 % dari standart BKI, daya yang dibutuhkan saat emergency adalah 4665 Watt untuk arus DC dan 18336 Watt untuk arus AC, perancangan system emergency generator sangat penting untuk mempercepat tanggap darurat kelistrikan pada kapal, komponen yang ditambahkan sesuai dari hasil rancangan tersebut, pengaman dan luas penampang yang digunakan untuk menyupply daya dari emergency generator ditentukan berdasarkan standart BKI, dimana arus pada Panel battery charge sebesar 8,7 Ampere, General Lighting Panel sebesar 14,7 Ampere, dan Galley panel sebesar 25 Ampere. Kata kunci : Peralatan emergency, daya emergency, rancangan system emergency, komponen emergency, pengaman dan lias penampang system emergency, simulasi system emergency


Abstract

ANALYSIS SYSTEM ELECTRICAL EMERGENCY ON KMP SABUK NUSATARA SHIP AT PT F1 PERKASA Electrical emergency system on the ship is a very important part in the operation of the ship. Emergency system design / electrical emergency right to provide security and safety to the ship and all its contents are significant in operation during a black out conditions on the ship. Black Out The condition is a condition in which the primary source of propulsion, auxiliary machinery and other equipment on the ship was not operating due to lack of power supply caused by the failure of the electrical system. Studies are necessary then separately address this issue. In this thesis focused on the research equipment used in the event of an emergency electricity on the ship KMP Sabuk Nusantara, research the amount of electrical power required in the event of an emergency, the emergency generator and activation system battery 24 Volt DC, research components that are added to support the emergency generator system automation , research relationships and cross-sectional area cable safety system terhada emergency, and manufacturing simulation system emergency generator. All the studies were determined by standard BKI (Biro Classification Indonesia). To obtain the results of the analysis method is done by analyzing secondary data from the observation. Tools that turn on when an emergency occurs on the ship meets only 50% of the standard ICC, when emergency power is needed for the 4665 Watt and 18336 Watt DC current to AC current, emergency generator system design is essential to accelerate the emergency electricity on ships, components added according to the results of the design, safety and cross-sectional area that is used to supply all kinds of emergency power generators are determined by standard ICC, where the panel battery charge current of 8.7 Amperes, General Lighting panel of 14.7 Amperes, and Galley panel of 25 Ampere. Keywords: Emergency equipment, emergency power, emergency system design, component of emergency, safety and emergency system alias cross-section, a simulation system of emergency


Detil Peneliti

Dosen Pembimbing 1 :Edy Prasetyo Hidayat
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2011


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.