ANALISIS KERUSAKAN PADA OUTDOOR METERING CUBICLE (OMC) DI PT. PLN (Persero) PUSHARLIS UWP VI SURABAYA.

DEMAGE ANALYSIS ON OUTDOOR METERING CUBICLE (OMC) AT PT. PLN (PERSERO) PUSHARLIS UWP VI SURABAYA.

Novita Sari (6410030009)


Abstrak

ABSTRAK PT. PLN PUSHARLIS UWP VI SURABAYA mengelola jasa perakitan Pole Mounted Circuit Breaker-recloser (PMCB-r), Outdoor Metering Cubicle (OMC), Panel Hubung Bagi-Tegangan Rendah (PHB-TR) dan perbaikan transformator 20 kV. OMC merupakan panel alternatif pengganti gardu beton karena dari segi biaya pemasangan yang lebih murah daripada gardu beton dan hemat tempat. Permasalahan yang terjadi pada OMC selama tiga tahun ini adalah sering terjadi berbagai kerusakan pada komponen ? komponennya akibat gangguan internal dan eksternal sehingga dapat mempengaruhi kinerja OMC. Pada Tugas Akhir ini dibahas mengenai kerusakan OMC akibat gangguan internal yaitu bushing elastimold terbakar pada fasa R, S dan T yang disebabkan oleh perubahan cuaca (panas atau dingin), kemudian Vacuum Circuit Breaker (VCB) terbakar hingga menjadi rusak, bilik vacuum pada VCB pecah dan berlubang pada fasa R, S, T serta bushing isolator terbakar yang disebabkan oleh sambaran petir. Selain itu Current Transformer (CT) terbakar pada salah satu fasa yang disebabkan oleh petir juga. Kemudian dibahas mengenai kerusakan OMC akibat gangguan internal yaitu switching power supply dengan output 12 V 20 A sering mengalami kerusakan. Solusi untuk mengatasi dan mencegah kerusakan OMC akibat gangguan eksternal antara lain mengganti bushing elastimold menjadi bushing isolator yang terbuat dari bahan porselin, mengganti VCB, bushing isolator, heat shrink baru serta memasang Fuse Cut Out (FCO) dan Lightning Arrester (LA) untuk mencegah terjadinya sambaran petir. Sedangkan untuk mengatasi dan mencegah kerusakan OMC akibat gangguan internal yaitu mengganti switching power supply dengan kapasitas 12 V 20 A menjadi 12 V 30 A dikarenakan tidak dapat memenuhi kapasitas beban yang ada. Kata kunci : OMC, VCB, bushing, CT, FCO, LA dan switching power supply


Abstract

ABSTRACT PT. PLN PUSHARLIS UWP VI SURABAYA manage assembly services Pole Mounted Circuit Breaker-recloser (PMCB-r), Outdoor Metering Cubicle (OMC), Connecting and Devide Panel For Low-Voltage (PHB-TR) and 20 kV transformer repairs. OMC is an alternative to the panel because of the terms of the concrete substation installation costs are cheaper than concrete substation and efficient place. Problems occurred in the OMC for three years it was often the case of damage due to its components ? internal and external disturbances can affect the performance of the OMC. In this Final Project is discussed about the damage caused by internal disorder that OMC elastimold bushing burning on the R, S and T are caused by changes in the weather (hot or cold), then burning to a damaged Vacuum Circuit Breaker (VCB), vacuum chambers on VCB broke out and perforated on the R, S, T and bushing insulators on fire caused by lightning strikes. In addition a Current Transformer (CT) burned in one of the phases that are caused by lightning strikes, too. Then discussed about the damage caused by internal disorder OMC is switching power supply with output 12 V 20 A are often damaged. Solutions for addressing and preventing damage due to external disturbances OMC include replacing the elastimold bushing to be insulator bushing made from porcelain, replace Insulators bushings, VCB, heat shrink and install new Fuse Cut Out (FCO) and Lightning Arrester (LA) to prevent the occurrence of lightning strikes. As for addressing and preventing damage caused by internal disorder that OMC replacing switching power supply with a capacity of 12 V 20 A to 12 V 30 A because can not meet the weight capacity. Keywords: OMC, VCB, bushing, CT, FCO, LA and the switching power supply


Detil Peneliti

Dosen Pembimbing 1 :Isa Rachman
Dosen Pembimbing 2 : Isa Rachman

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.