ANALISIS KERUSAKAN TRANSFORMATOR DISTRIBUSI 3 PHASE 200 kVA Di PT. PLN (PERSERO) UWP VI SURABAYA

DAMAGE ANALYSIS OF 3 PHASE DISTRIBUTION TRANSFORMER 200 KVA AT PT. PLN (PERSERO) UWP VI SURABAYA

Isnia Novita Chahayani (6410030006)


Abstrak

ANALISIS KERUSAKAN TRANSFORMATOR DISTRIBUSI 3 PHASE 200 kVA Di PT. PLN (Persero) UWP VI SURABAYA Oleh: Isnia Novita Chahayani (6410030006) Pembimbing Urip Mudjiono, ST., MT. NIP. 196805271994031002 Transformator merupakan bagian yang sangat penting dari suatu sistem distribusi tenaga listrik. Hal ini memanfaatkan prinsip kerja dari transformator yang mampu mengubah tegangan tinggi menjadi tegangan rendah atau sebaliknya. Sering kali transformator mengalami masalah yang berhubungan dengan keadaan alam dan faktor intern pada transformator. Akibat transformator mengalami kerusakan dapat menimbulkan gangguan pada penyaluran listrik. Pada analisa untuk mengetahui jenis kerusakan transformator dilakukan melalui pembelajaran materi serta pengujian secara langsung pada transformator distribusi yang mengalami kerusakan. Pengetesan yang dilakukan ada tiga macam yaitu Tes Tahanan Isolasi, Tes TTR dan Hi-Pot test. Analisa dilakukan pada data yang didapat dari hasil pengetesan pada transformator. Pengolahan data diambil dari perbandingan hasil pengtesan dengan standart yang digunakan. Kerusakan transformator dapat diketahui dari keadaan fisik dan dari pengetesan yang dilakukan. Transformator dapat dikatakan rusak jika hasil pengetesan tahanan isolasi <20 M?, dan hasil TTR lebih atau kurang dari standart dengan toleransi 0,5% setra hasil hi-pot tes yang <41 kV. Dari dari hasil pengetesan akan diketahui kerusakan dan langkah reparasi yang harus dilakukan. Pengujian dilakukan harus sesuai dengan SOP yang ditentukan dan hasil pengetesan harus disesuaikan dengan standart pada SPLN. Hasil study kasus menunjukan kerusakan yang sering terjadi pada tranformator 200 kVA tahun 2012 adalah kerusakan pada lilitan transformator sebanyak 70% dari 10 transformator. Reparasi yang dilakukan adalah dengan cara menggulung ulang lilitan sesuai dengan jumlah lilitan yang ditentukan. Kata Kunci: Transformator, Tes Tahanan Isolasi, Tes TTR, Hi-Pot Tes,


Abstract

DAMAGE ANALYSIS OF 3 PHASE DISTRIBUTION TRANSFORMER 200 kVA at PT. PLN (Persero) UWP VI SURABAYA By: Isnia Novita Chahayani (6410030006) Pembimbing Urip Mudjiono, ST., MT. NIP. 196805271994031002 Transformer is a very important part of an electric power distribution system. It takes advantage of the working principle of transformer that converts high voltage to low voltage or vice versa. Transformers often have problems associated with natural conditions and internal factors on the transformer. Due to transformer damage may cause electrical distribution. In the analysis to determine the type of transformer damage done through the learning materials and test directly on distribution transformers were damaged. Testing is done there are three kinds of Insulation Resistance Test, Test TTR and Hi-Pot test. Analysis performed on the data obtained from the results of the test on the transformer. Processing the data retrieved from the comparison of the results with standard used. Transformer damage can be seen from the physical state and of the testing conducted. Transformer can be said to be broken if the results of testing insulation resistance of <20 M?, and TTR results more or less than the standard with a tolerance of 0.5% and Hi-Pot test results are <41 kV. From the results of the test will be known damage and repair steps that must be done. Testing must be done in accordance with the specified SOP and test results must be adjusted to the standard on SPLN. Case study results show that damage often occurs in the transformer is 200 kVA in 2012 damage to the transformer windings as much as 70% of the 10 transformers. Repairs are carried out is to rewinding in accordance with the prescribed amount. Keywords: Transformer, Insulation Resistance Test, Test TTR, Hi-PoT Tess,


Detil Peneliti

Dosen Pembimbing 1 :Urip Mudjiono
Dosen Pembimbing 2 : Urip Mudjiono

Program Studi : D3 - TEKNIK KELISTRIKAN KAPAL
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.