Redesign Sistem Ventilasi Udara Pada Floating Dock (Studi Kasus Pada Floating Dock 3000TLC Di PT. Adiluhung SaranaSegara Indonesia)

REDESIGN AIR SYSTEM VENTILATION ON FLOATING DOCK (CASE STUDY ON FLOATING DOCK 3000 TLC AT PT. ADILUHUNG SARANASEGARA INDONESIA)

Raymond Warta Kurnia (6313030087)


Abstrak

FLOATING DOCK 3000 TLC di PT. ADILUHUNG SARANASEGARA INDONESIA merupakan salah satu fasilitas utama yang digunakan untuk melakukan pengedockan kapal. Ruang pompa yang terletak pada deck paling bawah digunakan untuk pengoperasian memiliki sistem ventilasi sederhana yaitu blower yang yang mensuplai udara kedalam ruang pompa tersebut. Namun karena tidak ada sistem pendingin pada ventilasi tersebut jika udara pada saat itu panas maka ruang pompa juga panas, pada kenyataanya kondisi temperature sangat tinggi, berdasarkan pengambilan data yang telah dilakukan kondisi temperature udara sangat ekstrim yaitu mencapai 41.2 0C, sedangkan temperature normal pada saat bekerja menurut standart SNI 03-6572-2011 adalah 25.8 0C ? 27.1 0C dengan kriteria hangat nyaman hal ini menyebabkan ketidaknyamanan kru saat melakukan aktifitas didalam ruang pompa. Berdasarkan masalah tersebut dilakukan sebuah penelitian untuk mengkondisikan temperature dalam ruang pompa sesuai dengan standart dan metode yang dilakukan adalah mendesain ulang sistem ventilasi tersebut dengan menggunakan 3 metode yaitu, penambahn blower, desain pipa pendingin pada ducting, dan desain evaporative cooling, metode tersebut diperbandingkan setelah melakukan perhitungan kemudian dipilih perhitungan yang sesuai dan selanjutnya dilakukan perancangan. Perencanaan tersebut diharapkan mampu mengkondisikan temperature ruang pompa sesuai standart yang diguanakan dan kru floating dock dapat melakukan kegiatan pada ruang pompa secara maksimal


Abstract

FLOATING DOCK 3000 TLC PT. Adiluhung SaranaSegara indonesia is one of the major facilities that are used to perform docking ship. Pump room located on the lower deck is used for the operation has a simple ventilation system is a blower that supplies air into the pump chamber. However, because there is no cooling system vents when the air when it's hot then the pump room also hot, in fact the condition of temperature is very high, based on the data collection was done condition air temperature extremes which reached 41.2 0 C, while the temperature normal at work according to standard ISO 03-6572-2011 is 25.8 0C - 27.1 0C with warm cozy criteria inconvenience this causes the crew when performing activities within the pump room. Based on the issue conducted a study to condition the temperature inside the pump chamber in accordance with the standards and methods that are redesigning the ventilation system by using three methods, namely, the addition of a blower, the design of cooling pipes in the ducting, and the design of evaporative cooling, the methods were compared after calculation then selected calculations accordingly and then performed the design. The planning is expected to be able to condition the temperature of the pumping chamber to the standard floating dock crews to use and can perform activities in the pumping chamber to the maximum


Detil Peneliti

Dosen Pembimbing 1 :George Endri K
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2013


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.