Analisa Performance Pompa Sentrifugal type 201-P-05A-M di PT TPPI Tuban

Analysis Performance of Centrifugal Pump type 201 - P - 05A - M at PT TPPI Tuban

Ardiansyah Prasetya (6313030079)


Abstrak

Pompa sentrifugal berfungsi memindahkan fluida dari satu tempat ke tempat lain dengan cara menaikan energi yang di pindahkan. Aplikasi pompa sentrifugal banyak di jumpai di dunia industri, salah satunya di PT. Trans Pacific Petrochemical Indotama (TPPI) Tuban. Di perusahaan tersebut pompa sentrifugal type 201-P-05A-M mengalami penurunan performance dari kapasitas barunya dikarenakan lamanya usia pemakaian pompa. Perhitungan performa pompa sentrifugal type 201-P-05A-M pada Tugas Akhir ini menggunakan metode Darcy Wiesbach. Dari perhitungan tersebut didapatkan nilai kapasitas pompa, head losses minor, head losses mayor, total head pompa, dan daya pompa yang nantinya dibandingkan dengan data pompa saat kondisi baru. Berdasarkan dari hasil data pompa diketahui bahwa kapasitas pompa sentrifugal 201-P-05A-M pada saat sebelum mengalami penurunan adalah 0,10 m3/s, Head pompa sebesar 36,1 m dan daya pompa sebesar 30 kW. Sedangkan dari hasil perhitungan kapasitas pompa sentrifugal 201-P-05A-M pada saat menurun sebesar 0,096 m3/s, head pompa sebesar 21,153 m, dan daya pompa sebesar 25,51 kW. Dari hasil perhitungan dan analisa dapat disimpulkan bahwa nilai kapasitas, head total, dan daya pompa terjadi penurunan performa.


Abstract

Centrifugal pump fluid serves to move from one place to another by raising energy on the move. Centrifugal pump applications encountered in many industrial world, one at PT. Trans Pacific Petrochemical INDOTAMA (TPPI) Tuban. In the enterprise-type centrifugal pump 201-P-05A-M decreased performance of his new capacity due to the length of the service life of the pump. The calculation of the performance-type centrifugal pump 201-P-05A-M in this final project using Darcy Wiesbach. The calculation of the value obtained from the pump capacity, minor head losses, head of major losses, total head pump, and the pump power that will be compared with data pump when the new conditions. Based on the results of the data is known that the pump capacity centrifugal pump 201-P-05A-M at the time before the decline was 0.10 m3 / s, Head pump of 36.1 m and a pump power of 30 kW. While the results of the calculation capacity centrifugal pump 201-P-05A-M at the time of a decrease of 0.096 m3 / s, the pump head of 21.153 m, and the pump power of 25.51 kW. From the calculation and analysis can be concluded that the value of capacity, total head and pump power decreased performance.


Detil Peneliti

Dosen Pembimbing 1 :Priyo Agus Setiawan
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2013


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.