ANALISA PERFORMA LOW PRESSURE HEATER 6 UNIT #2 PLTU 1 JAWA TIMUR, PACITAN DENGAN METODE EFFECTIVENESS -NTU

PERFORMANCE ANALYSIS OF LOW PRESSURE HEATER 6 UNIT #2 PLTU 1 JAWA TIMUR, PACITAN WITH EFFECTIVENESS-NTU METHOD

Setia Karnia Watik (6313030072)


Abstrak

ANALISA PERFORMA LOW PRESSURE HEATER 6 UNIT #2 PLTU 1 JAWA TIMUR, PACITAN DENGAN METODE EFFECTIVENESS - NTU Nama Mahasiswa : Setia Karnia Watik NRP : 6313030072 Dosen Pembimbing : Dr.Eng. M. Anis M., ST., MT ABSTRAK Alat penukar panas merupakan komponen yang sangat penting dalam suatu industri yang melibatkan transfer panas seperti pembangkit listrik. Salah satu alat penukar panas tersebut adalah Low Pressure Heater. Low Pressure Heater yang terpasang di PLTU 1 Jawa Timur, Pacitan bertipe Shell and Tube dengan susunan pipanya berupa pipa U. Proses pemanasan awal air umpan pada Low Pressure Heater ditentukan oleh besarnya tekanan dan temperatur pada unit tersebut. Kedua faktor tersebut harus dijaga agar selalu berada pada nilai standar yang ditetapkan. Namun suatu peralatan yang dioperasikan secara terus menerus dalam rentang waktu yang cukup lama akan mengalami penurunan performa. Hal ini mungkin saja terjadi pada Low Pressure Heater 6 unit #2 di PLTU 1 Jawa Timur, Pacitan. Untuk mengetahui performa Low Pressure Heater 6 unit #2 di PLTU 1 Jawa Timur, Pacitan selama empat tahun terakhir penulis menggunakan metode Effectiveness ? NTU. Metode Effectiveness ? NTU merupakan suatu metode yang cocok digunakan untuk analisis performa dari suatu Heat Exchanger yang sudah ada. Sehingga dapat diketahui seberapa besar efektivitas serta nilai maksimal yang diberikan oleh Low Pressure Heater 6 Unit #2 tersebut. Dalam hal ini nilai yang dihitung adalah nilai Tc,out maksimal dan Qtotal yang dapat dicapai oleh unit Low Pressure Heater. Dari proses perhitungan menggunakan metode kalkulasi Effectiveness ? NTU diperoleh hasil bahwa nilai Effectiveness pada tahun 2013, 2014, 2015 dan 2016 terjadi penurunan rata-rata sebesar 1.67% setiap tahunnya, dimana nilai Effectiveness tertinggi pada tahun 2013 yaitu 1 dan nilai Effectiveness terendah pada tahun 2016 yaitu 0.9421. Dari nilai tersebut, meskipun terjadi penurunan namun nilai Effectivenessnya masih di atas 85%. Sehingga Low Pressure Heater 6 Unit #2 masih menunjukkan kinerja yang maksimal. Kata kunci : Shell and Tube, Low Pressure Heater, Effectiveness-NTU, Heat Exchanger


Abstract

PERFORMANCE ANALYSIS OF LOW PRESSURE HEATER 6 UNIT #2 PLTU 1 JAWA TIMUR, PACITAN WITH EFFECTIVENESS-NTU METHOD Nama Mahasiswa : Setia Karnia Watik NRP : 6313030072 Dosen Pembimbing : Dr.Eng. M. Anis M., ST., MT ABSTRACT Heat exchanger is an important component in field of industry that involves the transfer of heat such as power plants. One of them is Low Pressure Heater. Low Pressure Heater installed in the power plant 1 East Java, Pacitan is a Shell and Tube-type with a pipe arrangement U. The process of heating the feed water in Low Pressure Heater is determined by pressure and temperature on the unit. Both of these factors must be kept in order to always be on the standards set value. However, an apparatus which is operated continuously for a long time definitely decreased performance. It is possible in Low Pressure Heater 6 unit # 2 at the power plant 1 East Java, Pacitan. For knowing the performance of Low Pressure Heater 6 Unit # 2 over the last four years writer using the effectiveness ? NTU method. The effectiveness ? NTU method is a method suitable to analysis performance of Heat Exchanger. So it can be known how much effectiveness and maximal values provided by Low Pressure Heater 6 Unit # 2 was. The maximal values which calculated is Tc,out and Qtotal of Low Pressure Heater 6 Unit # 2 Measurement process used both calculation methode effectiveness-NTU give a result that effectiveness values obtained in 2013, 2014, 2015 and 2016 was decline in 1.67% every years, where the maximum values at 2013 with effectiveness is 1 and the minimum values at 2016 with effectiveness is 0.9421. Although the effectiveness values was decline but it still more 85%. With the result that Low Pressure Heater 6 Unit # 2 is still has the maximum performance. Keywords : Shell and Tube, Low Pressure Heater, Effectiveness-NTU, Heat Exchanger


Detil Peneliti

Dosen Pembimbing 1 :Muhammad Anis Mustaghfirin
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2013


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.