Perancangan Sistem Pengkondisian Udara Dengan Metode Sistem Constant Air Volume (Studi Kasus Pada Kapal Utility Vessel SV. Prospero 10)

16The Design Of Air Conditioning Systems With Constant Air Volume System Method (A Case Study On The Ship SV. Prospero 10 Utility Vessel)

Khusnul Fitriana (6313030070)


Abstrak

SV. Prospero 10 merupakan kapal supply yang beroperasi di perairan Indonesia lebih khususnya di pulau Jawa. Kapal tersebut memiliki sistem pengkondisian udara basis Heating Ventilation and Air Conditioning (HVAC). Untuk mengatasi penghematan energi, sistem refrigrasi diperbaiki dan dimodifikasi sehingga ditentukan salah satu sistem untuk menghemat energi yaitu sistem Constant Air Volume (CAV). Pada tugas akhir ini bertujuan untuk merancang sistem pengkondisian udara yang hemat energi dengan menggunakan sistem Constant Air Volume (CAV). Pada sistem ini terdapat suatu alat yang dinamakan CAV controller yang berfungsi untuk mengatur kapasitas udara yang menuju ke ruangan. Perancangan sistem pengkondisian udara pada tugas akhir ini diaplikasikan pada kapal utility vessel SV. Prospero 10. Pada perancangan tugas akhir ini menggunakan 1 Air Handling Unit yang dapat memenuhi kapasitas beban pendingin sebesar 28.71 kW. Sistem ducting telah direncanakan dengan menyesuaikan space di kapal. Pada sistem CAV terdapat damper yang terletak pada CAV controller yang akan bergerak terus menerus menyesuaikan suhu yang berada di ruangan sehingga suhu tetap konstan dan daya fan pada Air Handling Unit dan fan supply akan tereduksi, sehingga sistem ini dapat menghemat energi sekitar 10%-30%. Kata Kunci : Pengkondisian Udara, Heating Ventilation and Air Conditioning (HVAC), Constant Air Volume (CAV), Air Handling Unit (AHU)


Abstract

SV . Prospero 10 is a supply vessel operating in Indonesian waters more especially in Java . The vessel has a base of air conditioning systems Heating Ventilation and Air Conditioning ( HVAC ) . To cope with energy savings , improved refrigeration system and modified so determined one system to conserve energy system ie Constant Air Volume ( CAV ) . In this final project aims to design an air conditioning system that is energy efficient by using a system of Constant Air Volume ( CAV ) . In this system there is a device called CAV controller that serves to regulate the capacity of the air leading into the room . The design of the air conditioning system in this final task was applied to SV. Prospero 10 of the ship utility vessels . In designing this thesis using 1 Air Handling Unit to meet the cooling load capacity of 28.71 kW . Ducting system has been planned by adjusting the space in the vessel . In the CAV system there damper located at CAV controller that will move continuously adjust the temperature in the room so the temperature remains constant and the power of fans at Air Handling Unit and fan supply will be reduced , so that the system can save energy around 10 % -30 %. Keywords : Air Conditioning , Heating Ventilation and Air Conditioning( HVAC ) , Constant Air Volume ( CAV ) , Air Handling Unit ( AHU )


Detil Peneliti

Dosen Pembimbing 1 :George Endri K
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2013


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.