PENGARUH OVERHEATING TERHADAP KINERJA KOMPRESOR K-101A AREA 100 (study kasus di PT. ALP PETRO INDUSTRY)

EFFECT OVERHEATING OF PERFORMANCE COMPRESOR K-101A AREA 100 (case study in PT. ALP PETRO INDUSTRY)

Tri Febri Setiono (6312030051)


Abstrak

ABSTRAK Overheating tidak dapat dikesampingkan pada kompresor. Pendingin kompresor menjadi masalah utama apabila terjadi overheat. Kompresor berhenti dengan sendirinya apabila temperatur keluar hidrogen melebihi batas maksimal. Berhentinya kompresor akan menggangu proses hydrofinishing. Sehingga penjernihan base oil tidak akan bisa dilakukan. Beban panas yang diakibatkan overheating bisa diketahui dengan melakukan perhitungan. Perhitungan yang dilakukan menentukan daya, efisiensi kompresor pada kondisi normal dan overheat. Kemudian mengetahui kelebihan panas yang diterima kompresor. Beban panas yang diterima water cooler pada kondisi normal dan overheat. Analisa dan perhitungan yang dilakukan mendapatkan hasil bahwa kondisi normal mempunyai daya aktual sebesar 46.24 kw. Overheat mengakibatkan kenaikan daya aktual sebesar 19.3%. Kelebihan panas kompresor sebesar 11.03 kw dan beban panas water cooler meningkat 50% dari 1.04 kw. Efisiensi kompresor terjadi penurunan 15.7% dari keadaan normal sebesar 75.8% Kata Kunci : Beban Panas, Daya, Kompresor, Efisiensi


Abstract

ABSTRACT Overheating can not be ruled out on the compressor. Cooling system compressor becomes a major problem in the event of overheating. The compressor stops by itself when the exit temperature hydrogen exceeds the maximum limit. The cessation of the compressor would interfere hydrofinishing process. So that base oil purification can not be carried out. Heat load caused by overheating can be known by doing the calculation. Calculations were performed determining, compressor efficiency under normal conditions and overheat. Then knowing excess heat received by the compressor. Heat load received water cooler in normal conditions and overheat. Analysis and calculations are done to get the result that normal conditions have the actual power of 46.24 kW. Overheat resulting in the increase amounted to 19.3% of actual power. Excess heat at 11:03 kw compressor and heat load increase of 50% water cooler from 1:04 kw. Compressor efficiency decreased 15.7% from the normal state at 75.8% Keywords: Load Heat, Power, Compressors, Efficiency


Detil Peneliti

Dosen Pembimbing 1 :Muhammad Anis Mustaghfirin
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2012


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.