ANALISA PENURUNAN PERFORMA GENERAL SERVICE PUMP KT.JOYOYBOYO 1 SAAT MENGALAMI KERUSAKAN SEAL

PERFORMANCE LOSS ANALYSIS OF GENERAL SERVICE PUMP KT. JOYOBOYO 1 WHEN HAVE SEAL DAMAGE

Asnafiyah (6312030013)


Abstrak

Sistem pompa dinas umum (general service pump) adalah salah satu sistem yang penting pada kapal. Ketika sistem tersebut sedang bermasalah, maka akan mengakibatkan gangguan pada kinerja general service pump tersebut. General service pump khusus pemadam tersebut berguna di saat pompa utama pemadam kebakaran pada KT. JOYOBOYO 1 sedang rusak atau tidak bisa beroperasi. Jadi general service pump akan beroperasi menggantikan pompa pemadam yang rusak tersebut. Pada general service pump KT. JOYOBOYO 1 ini menggunakan pompa sentrifugal. Pompa tersebut tidak bisa bekerja dengan optimal diakibatkan kerena menurunnya performa kinerja pada general service pump yang mengalami kerusakan pada bagian seal. Penurunan performa yang terjadi pada pompa tersebut dapat diatasi dengan melakukan perbaikan dan pergantian komponen seal yang telah rusak. Kerusakan pada seal biasanya diakibatkan oleh kotoran yang mengendap, as aus atau mechanic seal sudah kaku (tidak lentur lagi). Pada kondisi seal mengalami kerusakan sesuai dengan perhitungan performa pompa secara manual diketahui bahwa kapasitas pompa dinas umum sebesar 0,0025 m3/s, Head Pompa sebesar 21,2 m, Head Losses sebesar 0,0872 m, dan daya yang dibutuhkan pompa sebesar 0,665 kw. Sedangkan menurut perhitungan dari spesifikasi general service pump menunjukkan kapasitas sebesar 0.0078 m3/s, tekanan pompa sebesar 4 bar, head total pompa sebesar 36,97 m, head Losses pompa sebesar 0,847 m , dan daya yang dibutuhkan pompa sebesar 7,5 kw. Dari hasil analisa dan perhitungan disimpulkan bahwa general service pump tersebut telah mengalami penurunan performa. Kata Kunci : General service Pump, Centrifugal Pump, Performance


Abstract

General service pump system is one of the important systems on ships. When the system is in trouble, then it will cause interference with the performance of general service pump. General service pump the extinguishing specifically useful when the main pump firefighters at KT. JOYOBOYO 1 being damaged or inoperable. So the general service pump will operate replace the damaged fire pump. In the general service pump KT. JOYOBOYO 1 using a centrifugal pump. The pump can not work optimally because they caused the declining performance of the performance in general service pump was damaged in the seal. Loss in performance occurs at the pump can be overcome by performing repair and replacement parts that have been damaged seal. Damage to the seal is usually caused by a buildup of dirt, as worn or mechanic seal already rigid (not flexible anymore). On the condition of seal damage in accordance with the calculation of the performance of the pump manually in mind that the general service pump capacity amounted to 0.0025 m3 / s, Head Pumps 21.2 m, Head Losses amounted to 0.0872 m, and the pump power needed for 0.665 kw , Meanwhile, according to the calculations of the specification indicates general service pump capacity of 0.0078 m3 / s, the pump pressure of 4 bar, the pump head total of 36.97 m, the pump head Losses amounted to 0.847 m, and the required pump power of 7.5 kw. From the analysis and calculations concluded that the general service pump have decreased performance. Keywords: General Service Pump, Centrifugal Pump, Performance


Detil Peneliti

Dosen Pembimbing 1 :Arief Subekti
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2012


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.