ANALISA EFISIENSI KONSUMSI DAYA DRIVING SHAFT MOTOR PENGGERAK TERHADAP DAYA LISTRIK AKIBAT PERUBAHAN VOLUME BUCKET ELEVATOR BE 619

EFFICIENCY POWER CONSUMPTION ANALYSIS ON DRIVING SHAFT MOTOR DRIVE TOWARD ELECTRIC POWER DUE TO VOLUME CHANGES OF BUCKET ELEVATOR 619 BE

Rido Nurohman (6311030045)


Abstrak

Penelitian ini mempelajari besarnya efisiensi daya driving shaft motor penggerak terhadap daya listrik akibat perubahan volume bucket elevator. Hal tersebut bertujuan untuk mengetahui persentase volume bucket dan kerja motor yang paling efisien. Untuk mengetahui efisiensi kerja motor dari Bucket Elevator BE 619 dilakukan perhitungan besarnya daya pada driving shaft motor penggerak, daya listrik yang disupplai dan daya maksimum motor. Dimana daya listrik merupakan daya input dan daya driving shaft sebagai daya output. Dari kedua daya tesebut akan diketahui nilai efisiensi pada masing-masing persentase volume. Arus yang tercatat yaitu dari yang terendah sebesar 80,1 ampere dan arus terbesar yaitu 117,6 ampere dengan persentase volume dari 48,07% sampai dengan 70,69%. Dari besarnya nilai deviasi terhadap persentase volume diperoleh 5 (lima) penggolongan atau cluster yaitu persentase volume antara 40-50 %, 51-55 % , 56-61 %, 62-65 %, dan 66-70 % . Hasil perhitungan yang mengacu pada jumlah semen yang terangkut diperoleh daya driving shaft terkecil sebesar 40 kW pada persentase volume 48,07 % dengan arus 80,1 ampere . Sedangkan daya driving shaft terbesar yaitu 58,83 kW diperoleh pada persentase volume 70,69 % dengan arus 117,6 ampere. Dan, dari hasil perhitungan yang mengacu pada desain Beumer diperoleh daya driving shaft terkecil sebesar 40,19 kW pada persentase volume 48,07 % dengan arus 80,1 ampere. Sedangkan daya driving shaft terbesar yaitu 59,01 kW diperoleh pada persentase volume 70,69 % dengan arus 117,6 ampere. Dari hasil Perhitungan diperoleh daya listrik terkecil sebesar 45,34 kW pada persentase volume 48,07 % dengan arus 80,1 ampere. Sedangkan daya terbesar yaitu 66,57 kW diperoleh pada persentase volume 70,69 % dengan arus 117,6 ampere. Kemudian, dari perhitungan besarnya nilai efisiensi terhadap daya listrik diperoleh efisiensi rata-rata adalah sebesar 88,24 % pada range persentase volume bucket antara 40-50 %. Untuk range persentase volume bucket antara 51-55 % efisiensi rata-rata diperoleh sebesar 88,68 %. Untuk range persentase volume bucket antara 56-61 % efisiensi rata-rata diperoleh sebesar 88,54 %. Untuk range persentase volume bucket antara 62-65 % efisiensi rata-rata diperoleh sebesar 88,84 %. Dan untuk range persentase volume bucket antara 66-70 % efisiensi rata-rata diperoleh sebesar 88,63 %. Selanjutnya, dari perhitungan besarnya nilai efisiensi terhadap daya maksimum motor penggerak diperoleh efisiensi rata-rata sebesar 44,62 % pada range persentase volume bucket antara 40-50 %. Untuk range persentase volume bucket antara 51-55 % efisiensi rata-rata diperoleh sebesar 50,96 %. Untuk range persentase volume bucket antara 56-61 % efisiensi rata-rata diperoleh sebesar 56,21 %. Untuk range persentase volume bucket antara 62-65 % efisiensi rata-rata diperoleh sebesar 59,22 %. Dan untuk range persentase volume bucket antara 66-70 % efisiensi rata-rata diperoleh sebesar 63,93 % . Dengan mempertimbangkan nilai efisiensi terhadap daya listrik dan daya maksimum motor penggerak, maka persentase volume 66-70 % adalah persentase volume yang efektif dan bisa menjadi acuan dalam pengoperasian Bucket Elevator BE 619. Kata Kunci : Bucket Elevator, Driving Shaft, Daya Listrik, Efisiensi


Abstract

This research studies the magnitude of the power efficiency of motor drive on driving shaft against electrical power due to changes in the volume of bucket elevators. That is have the goal is to find out the percentage of the bucket volume and the most efficient motor performance. To identify the performance efficiency of the motor Bucket Elevator 619 BE, used calculation carried out the value of driving shaft power, electric power were supplied, and maximum power of motor drive. Where the electric power as a input power and the driving shaft power as a output power. From the boths, will knew the value of efficiency in each volume percentage. The current were recorded from the smallest currents at 81,1 ampere and the largest currents is 117,6 ampere. From the deviation value of volume percentage gained 5 (five) categorization or cluster i.e volume percentage of between 40-50%, 55%, 51-56-61%, 62-65, and 66%-70%. The results of the calculation refers to the amount of cement transported obtained that the driving shaft power smallest at 40 kW at the volume percentage of 48,07% with the current of 80,1 ampere. While the largest of driving shaft power at 58,83 kW obtained at the volume percentage of 70,69 % with the current 117,6 ampere. And, from the result of the calculation refers to the design of Beumer gained the driving shaft power smallest of 40,19 kW at volume percentage of 48,07% with the current of 80,1 ampere. While the largest driving shaft power 59,01 kW obtained at the volume percentage of 70,69% with the current of 117,6 ampere. From the calculation results of the electrical power gained that the smallest power 45,34 kW at the volume percentage of 48,07% with the currents of 80,1 ampere. While the largest electric power 66,57 kW obtained at the volume percentage of 70,69% with the current 117,6 ampere. Then, from the calculation results of the efficiency value refers to the electrical power obtained average efficiency is 88.24% in the bucket volume percentage range between 40-50%. For a percentage of the bucket volume range between 51-55% obtained average efficiency of 88.68%. For a percentage of the bucket volume range between 56-61% obtained average efficiency of 88.54%. For a percentage of the bucket volume range between 62-65% obtained average efficiency of 88.84% . And for the bucket volume percentage range between 66-70% obtained average efficiency of 88.63%. Furthermore, from the calculation results of the efficiency value refers to the maximum power of motor drive gained an average of 44.62% in the bucket volume percentage range between 40-50%. For a percentage of the bucket volume range between 51-55% obtained average efficiency of 50.96%. For a percentage of the bucket volume range between 56-61% obtained average efficiency of 56.21%. For a percentage of the bucket volume range between 62-65% obtained average efficiency of 59.22%. And for the bucket volume percentage range between 66-70% obtained average efficiency of 63.93%. Taking into account the efficiency due to the electric power and the maximum power of the motor, the percentage volume of 66-70% is the volume percentage most effective and could be a reference to operation of Bucket Elevators 619 BE. Keywords: Bucket Elevator, Driving Shaft, Electric Power, Efficiency


Detil Peneliti

Dosen Pembimbing 1 :Adi Wirawan Husodo
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2011


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.