ANALISA PERFORMA HIGH PRESSURE FEEDWATER HEATER PADA BOILER UNIT 6 (STUDI KASUS DI PT.YTL JAWA TIMUR)

PERFORMANCE ANALYSIS OF HIGH PRESSURE FEEDWATER HEATER at BOILER UNIT 6 (CASE STUDY IN PT.YTL EAST JAVA)

Rizki Fitrotul Ulum (6311030036)


Abstrak

Heat exchanger merupakan salah satu komponen atau alat yang sangat vital keberadaannya pada siklus pembangkit listrik. Salah satu penggunaan heat exchanger ini pada system pembangkit listrik yaitu sebagai pemanas air pengisi boiler (boiler feedwater heater). Pada saat observasi di lapangan High Pressure Feedwater Heater jarang dilakukan perhitungan performance secara rutin. Feedwater heater digunakan pada system pembangkit sebagai pemanasan awal (pre-heat) air yang dikirim ke boiler penghasil uap. Mengingat begitu pentingnya peranaan feedwater heater bagi efisiensi penggunaan bahan bakar batubara pada PLTU ini, maka dimungkinkan untuk dilakukan perhitungan ulang performance terhadap perpindahan panas pada HP feedwater heater sebagai optimalisasi penggunaannya. Setelah dilakukan perhitungan performance dengan berdasarkan spesifikasi maka perusahaan akan mengetahui performance High Pressure Feedwater Heater masih layak digunakan atau tidak dengan perbandingan efficiency batu bara. Jika performance High Pressure Feedwater Heater menurun maka konsumsi batu bara yang digunakan untuk memanaskan boiler akan semakin banyak dan tentunya tidak menguntungkan bagi perusahaan


Abstract

Heat exchangers are one of the components or tools that are vital presence in the power generation cycle. One is the use of heat exchangers in the power generation system that is as filler boiler water heater (boiler feedwater heater). At the time of observation in the field of High Pressure Feedwater Heater performance calculation is rarely done on a regular basis. Feedwater heater used on plants as a preheating system (pre-heat) of water delivered to the boiler producing steam. Given the importance of peranaan feedwater heater for the fuel efficiency of coal at the power plant, it is possible to do re-calculation of the heat transfer performance of the HP feedwater heater as optimizing its use. After calculation of the performance based specifications, the company will know the performance of High Pressure Feedwater Heater is still fit for use or not with the efficiency ratio coal. If the performance of High Pressure Feedwater Heater decreased coal consumption is used to heat the boiler will be more and more and certainly not profitable for the company.


Detil Peneliti

Dosen Pembimbing 1 :George Endri K
Dosen Pembimbing 2 :

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2011


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.