ANALISA PENYEBAB TRIPED FAN AHU PADA SISTEM SALURAN UDARA KAPAL TANKER MT. MATINDOK 3500 LTDW

CAUSE ANALYSIS OF TRIPED FAN AHU AT AIR DUCT SYSTEM OF TANKER SHIP MT. MATINDOK 3500 LTDW

Adif Masrukhin (6310030036)


Abstrak

Sistem pengkondisian udara merupakan sistem penunjang kenyamanan untuk mengkondisikan udara agar ABK tidak mudah lelah dan tidak mudah melakukan kesalahan. Pada kenyataanya sistem pengkondisian udara yang dipasang pada MT.Matindok 3500 LTDW tidak dapat bekerja dengan baik karena fan AHU mengalami triped saat pengoperasian.Triped padafan AHU membuat udara yang dikondisikan di dalam evaporator tidak dapat mengalir menuju ruangan yang dikondisikan. Hal ini membuat suhu ruangan yang dikondisikan tidak tercapai bahkan terus meningkat akibat rambatan panas dari luar dan peralatan yang menimbulkan panas. Kondisi yang demikian akan cenderung membuat ABK mudah lelah dan mudah melakukan kesalahan. Menanggapi permasalahan diatas perlu adanya analisis penyebab terjadinya triped pada fan AHU. Perhitungan ulang pressure drop yang terjadi pada saluran udara perlu dilakukan. Pressure drop yang terjadi dibandingkan dengan head pressurepada spesifikasi fan untuk mendapatkan kesimpulan dan acuan dalam perbaikan sistem saluran udara pada kapal tanker MT. Matindok 3500 LTDW. Dari hasil perhitungan pressure drop pada sistem saluran udara kapal tanker MT. Matindok 3500 LTDW didapatkan pressure drop yangterjadi sebesar 2737,71Pa dalam selang waktu 82,48 s (metode perhitungan manual) dan 2843,97 Pa dalam selang waktu 98,16 s (metode perhitungan software). Besarnya pressure drop melebihi head pressuremaksimal fan sebesar 1848 Pa sehingga beban dayafan AHU overload dan triped. Kata kunci : Fan AHU, Saluran Udara, Pressure Drop,Over Load, Triped


Abstract

Air conditioning system is a support system for the comfort to conditioned air so crews do not get tired and make mistake easily. In fact the air conditioning system which is installed in MT. Matindok 3500 LTDW can not work properly because AHU?s fan get triped during an operation. Triped of AHU?s fan make the air which is conditioned in evaporator can not flow to conditioned room. This condition makes the conditioned room?s temperature is not reached instead the temperature continue to rise because heat transfer from out side room and equipment which generate heat. This condition would tend to make crew tired and make mistake easily. Respond the problem above, its need for analysis of the cause triped on AHU?s fan. Recalculation of pressure drop that occurs in air duct system need to be done. Pressure drop that occurs is compared with head pressure on the fan?s specification to get conclusion and references to repair the air duct system on MT. Matindok 3500 LTDW. From the calculation of pressure drop in air duct system in MT. Matindok 3500 LTDW. The value of pressure drop is 2737,71 Pa in interval 82,48 s (manual calculation method) and 2843,97 Pa in interval 98,16 s (software calculation method). The amount of pressure drop is higher than maximum head pressure of fan which is 1848 Pa so load of AHU?s fan power is overload and triped. Keywords : Fan AHU, Air Line, Pressure Drop,Over Load, Triped


Detil Peneliti

Dosen Pembimbing 1 :George Endri K
Dosen Pembimbing 2 : George Endri K

Program Studi : D3 - TEKNIK PERMESINAN KAPAL
Angkatan : 2010


Untuk mendapatkan versi full dari dokumen penelitian ini, Anda dapat melihat koleksi Buku Tugas Akhir di Perpustakaan Politeknik Perkapalan Negeri Surabaya pada jam kerja. Atau Anda dapat menghubungi penulis secara personal.