PERHITUNGAN DAYA SW COOLING PUMP UNTUK PENDINGIN AC CENTRAL DI KAPAL KELAS 1 KENAVIGASIAN

Santoso, Arif Tri (2017) PERHITUNGAN DAYA SW COOLING PUMP UNTUK PENDINGIN AC CENTRAL DI KAPAL KELAS 1 KENAVIGASIAN. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Sea water cooling pump merupakan pompa yang berfungsi untuk mendinginkan kondensor. Komponen ini berpengaruh terhadap pengkondisian udara, karena dapat membuat ruangan menjadi nyaman dan sejuk. Terutama pada ruang akomodasi kapal yang harus dijaga suhu udaranya agar penumpang atau orang yang ada didalam ruangan tersebut merasa nyaman. Permasalahan yang terjadi di kapal kelas 1 kenavigasian adalah belum dihitungnya daya sea water cooling pump. Sea water cooling pump harus dipastikan dapat memenuhi kapasitas air pendingin yang dibutuhkan untuk mendinginkan uap refrigerant yang ada di kondensor. Fokus penelitian yang digunakan sebagai tugas akhir penulis adalah menghitung daya SW cooling pump untuk pendingin AC central di Kapal Kelas 1 Kenavigasian. Dari hasil perhitungan tersebut, diketahui head losses 11,794 m, head pump 23,528 m serta daya pompa 2,790 KW. Data yang dihasilkan dari perhitungan tersebut digunakan untuk pemilihan pompa dengan spesifikasi yang sesuai dengan hasil perhitungan agar kebutuhan daya pompa sea water cooling terpenuhi. Perhitungan dan pemilihan pompa tersebut menjadi referensi untuk perusahaan untuk membeli sea water cooling pump sesuai dengan perhitungan tersebut. Kata kunci : Daya Pompa, Pengkondisian Udara, Sea Water Cooling pump. ABSTRACT Sea water cooling is the pump which serves to cool the condenser. This component effect on air conditioning, because it can make the room to be comfortable and cool. Especially in the accommodation vessel must be kept air temperature for the passenger or the person who is in the room feel comfortable. The problems that occurred in the ship 1st class navigation is not yet counted resources sea water cooling pump. This sea water cooling pump must also be able to meet capacity cooling water required to cool steam refrigerant that is in a condenser. Focus research used as a final project of the writer is counting sw cooling power to pump cooling ac central in a ship 1st class navigation. From the these calculations, known head losses 11,794 m, head pump 23,528 m and power pump 2,790 KW. Resulted data from these calculations used for an election pump with the specifications in accordance with the calculation on in order for the needs pump power sea water cooling fulfilled. Calculation and the election of the pump is being reference to a company to buy sea water pump cooling according to these calculations. Keywords : Air Conditioning, Power Pump, Sea Water Cooling pump.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Permesinan Kapal > D3 Teknik Permesinan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 19 Sep 2018 06:47
Last Modified: 19 Sep 2018 06:47
URI: http://repository.ppns.ac.id/id/eprint/964

Actions (login required)

View Item View Item