Saputra, Dardiri Jaya (2017) PERENCANAAN SISTEM SALURAN UDARA PADA RUANG AMUNISI KAPAL LANDING PLATFROM DOCK (LPD) DI PT. PAL INDONESIA. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.
Full text not available from this repository.Abstract
ABSTRAK Kapal Landing Platform Dock (LPD) yang akan dibangun di PT. PAL INDONESIA merupakan jenis kapal perang yang dirancang untuk membawa pasukan ke zona pertempuran dan membawa berbagai peralatan untuk perang. Kapal Landing Platform Dock memiliki ruangan yang disebut ammunition room. Ammunition room / ruang amunisi memiliki fungsi menyimpan amunisi pada temperatur dan kelembapan tertentu. Untuk memenuhi persyaratan temperatur dan kelembapan tersebut dibutuhkan pengkondisian udara menggunakan AHU (Air Handling Unit). Metode perhitungan yang digunakan pada pembahasan ini merupakan langkah-langkah perencanaan sistem saluran udara secara berurutan yang dimulai dari pengambilan data, perhitungan beban pendingin ruangan, perhitungan kebutuhan kapasitas udara yang disuplai, perhitungan kapasitas AHU, dan perhitungan daya fan. Perhitungan beban pendingin total yang diderita ruangan yang dikondisikan pada tugas akhir ini harus sesuai standart yang berlaku. Dari proses perhitungan dari sistem saluran udara menggunakan standart yang ada dan didapatkan beban pendingin (cooling load) sebesar 1,467 kW, debit udara yang disuplai 0,399 � 3 � , kapasitas AHU sebesar 2,992 kW, temperatur yang dibutuhkan AHU 11°�, Daya fan yang dibutuhkan sistem saluran udara pada ruang amunisi sebesar 0,402 kW dengan kecepatan 12 m/s, effisiensi 80%, dan total tekanan pada saluran udara 806,112 Pa Kata kunci : AHU, Landing Platfrom Dock, Ruang amunisi, Sistem saluran udara. ABSTRACT A Landing Platform Dock (LPD) ship which will be built by PT. PAL INDONESIA is a warship designed to carry troops and battle equipment to combat zone. A Landing Platform Dock has a room called ammunition room. Ammunition room is used to keep the ammunition. At the designated temperature and humidity, To meet the required temperature and humidity, an air conditioning system is needed. The design process started sequentially from collecting the data, Calculating the flow rate of the cooling air, Calculating the AHU capacity, and fan power. The total calculated cooling load must conform to the applicable standards. The results show that the obtained cooling load is 1,467 kW, cooling air flow rate is 0,399 � 3 � , the capacity of the AHU is 2,992 kW, temperature difference required in the AHU unit is 11°�, and fan power needed is 0,402 kW with velocity of 12 m/s , efficiency of 80 %, and the total pressure of 806,112 Pa. Keyword : AHU, Landing Platfrom Dock, Ammunition room, Air duct system.
Item Type: | Thesis (Diploma) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Jurusan Teknik Permesinan Kapal > D3 Teknik Permesinan Kapal |
Depositing User: | Unnamed user with email repository@ppns.ac.id |
Date Deposited: | 19 Sep 2018 06:35 |
Last Modified: | 19 Sep 2018 06:35 |
URI: | http://repository.ppns.ac.id/id/eprint/961 |
Actions (login required)
View Item |