PERANCANGAN ULANG SISTEM PENDINGIN LOAD BANK KAPASITAS 450 KW di PT. ORELA SHIPYARD

Gumelar, Rizqy Irfan (2017) PERANCANGAN ULANG SISTEM PENDINGIN LOAD BANK KAPASITAS 450 KW di PT. ORELA SHIPYARD. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Load bank adalah suatu alat yang dipakai untuk menguji kemampuan transformers, battery ataupun genset. Load bank bekerja dengan cara mengubah daya yang dihasilkan oleh generator menjadi energi panas. Dalam pengoperasianya, efektifitas pendinginan load bank menjadi tolok ukur dalam desain suatu load bank. Tantangan utama dalam sistem pendingin harus mampu menjaga agar pada saat load bank bekerja, heater tidak menglami overheating. Daya heater yang berbeda-beda menyebabkan beban pendinginan juga berbeda. Untuk itu dilakukan perancangan ulang posisi heater dan beban pendinginanya agar load bank bekerja secara optimal. Tahapan perhitungan perancangan pendingin load bank diawali menghitung luas keseluruhan permukaan heater. kedua mencari temperatur udara keluar dan temperatur permukaan heater. Selanjutnya mencari nilai pressure drop yang dihasilkan dan kebutuhan udara pendinginan. Dari hasil perhitungan dapat digunakan untuk pemilihan fan dan daya motor penggerak fan. Desain perhitungan yang telah dilakukan, diketahui bahwa permodelan posisi heater untuk load bank yang efektif adalah staggered 63 0 . Menghasilkan nilai pressure drop yang paling optimal sebesar 141.2 N/m 2 dengan temperatur permukaan heater sebesar 181 0 C. Untuk dapat bekerja secara optimal dan tidak terjadi overheating dipilihlah dua unit fan dengan diameter 450 mm dan kecepatan 2800 rpm yang di pasang pararel hingga menghasilkan debit udara masuk sebesar 4 m 3 /s. sehingga untuk menggerakkan fan tersebut dengan mengacu nilai pressure drop dan debit dipilihlah dua unit motor berkapasitas 0.75 KW/ 1 HP merek TECO tipe AEEB, IEC 60034-30 :2008 (IE1)380 v-50Hz. Kata kunci : Load bank, Heater, perpindahan panas, Pressure Drop, AHP. ABSTRACT Load bank is an equipment that used for testing transformers, batteries or generators. Load bank works by changing the power generated by a generator into thermal energy. During cooling effectivity of the load bank us an important factor. In designing a load bank. The cooling system should be able to hold the heater operational temperature. So it can not be overheated. The difference of heater power might variate to re-design heater position an its cooling load. So load bank can optimally work. Redesign will calculate : heater surface area, heater surface temperature, outlet air temperature, pressure drop value, and then air cooling needs. The result of the calculation, can be used to choosing the fan and its motor power. From the calculation, the result are the heater most effective configuration load bank is staggered 63 0 . It produces the lowlest pressure drop value of 141.2 N/m2 with 181 0 C heater surface temperature. To be able to work optimally without overheating, two fan with diameter of 450 mm and speed of 2800 rpm in pairs of series to produce incoming airflow of 4 m 3 /s. so to drive the fan by referring the value of pressure drop and discharge selected two motor capacity of 0.75 KW/ 1 HP merk TECO types AEEB, IEC 60034-30 :2008 (IE1)380 v-50Hz. Keywords: Load bank, Heater,Heat Transfer, Pressure Drop, AHP.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Permesinan Kapal > D3 Teknik Permesinan Kapal
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 19 Sep 2018 03:53
Last Modified: 19 Sep 2018 03:53
URI: http://repository.ppns.ac.id/id/eprint/934

Actions (login required)

View Item View Item