PENGARUH DEBIT PADA PIPA TERHADAP NILAI DENSITAS DAN SENSITIFITAS FILM DALAM PENGUJIAN RADIOGRAFI MENGGUNAKAN GAMMA-RAY IR 192

Gigih Margentha, Putra (2014) PENGARUH DEBIT PADA PIPA TERHADAP NILAI DENSITAS DAN SENSITIFITAS FILM DALAM PENGUJIAN RADIOGRAFI MENGGUNAKAN GAMMA-RAY IR 192. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK Pada penelitian ini pengujian radiografi divariasikan dengan adanya debit didalam sebuah pipa yang berukuran diameter 3 inchi dengan ketebalan 4 mm. Pengujian radiografi dilakukan agar mengetahui adanya pengaruh debit atau tidak, terhadap nilai densitas film radiografi. Pada penelitian ini menggunaan Kamera Gamma-ray Ir-192. Dengan besarnya sumber yaitu 12 curie, dengan kondisi didalam pipa terdapat aliran debit. Besarnya debit yaitu 0 liter/menit (tidak mengalir), 20 liter/menit dan 30 liter/menit. Dengan menggunakan perlakuan yang sama seperti Curie, Source to Film Distance dan Exposure Time. Dalam pengujian ini menggunakan syarat keberterimaan sesuai dengan standart ASME V 2010. Dari penelitian ini dapat diketahui bahwa debit berpengaruh terhadap densitas film radiografi. Pengujiaan dengan debit 0 liter/menit memiliki rata-rata densitas sebesar 1.75, debit 20 liter/menit rata-rata densitas sebesar 1.78 dan debit 30 liter/menit rata-rata densitas 1.79. Dalam syarat keberterimaan ASME V densitas tersebut tidak diterima. Penambahan Exposure Time dengan menggunakan Exposure Factor ini bisa digunakan untuk mendapatkan densitas yang diinginkan. Hasil dari pengujian kedua ini yaitu 0 liter/menit memiliki rata-rata densitas 2.29, kemudian debit 20 liter/menit memiliki rata-rata densitas 2.32 dan debit 30 liter/menit memiliki rata-rata densitas 2.30.Sehingga densitas dari pengujian ini sesuai dengan syarat keberterimaan ASME V 2010. Keyword: Gamma-ray Ir 192, debit,densitas,sensitifitas, source to film distance, exposure time,curie, ASME V. ABSTRACT In this study, radiographic testing varied with the flowin a pipe that measures 3 inches in diameter with a thickness of 4mm. Radiographic testing performed in order toi nvestigate the influence of discharge or not, the value of radiographic film density . In this study, uses the Gamma-ray Camera Ir-192. With the amount of resources that is 12 curies, with the conditions contained in the flow of the discharge pipe. The amount of discharge is 0 liters/minute (no flow), 20 liters/min and 30 liters/min. By using the same treatment as Curie, Source to Film Distance and Exposure Time. In this test the acceptability of the terms in accordance with standard ASME V 2010. From this study it can be seen that the discharge effect on radiographic film density . Testing with debit 0 liters/min had an average density of 1.75, the discharge 20 liters/min the average density of 1.78 and a flow of 30 liters/min the average density of 1.79. In terms of the acceptability of the ASME V density is not acceptable. Addition of using Exposure Time Exposure Factor can be used to obtain the desired density. The results of this second test is 0 liters/min had an average density of 2:29, then discharge 20 liters/min had an average density of 2:32 and discharge 30l iters/min had an average density of 2:30. So that the density of the test in accordance with the acceptance requirements of ASME V 2010. Keyword: Discharge,density,sensitifity, source to film distance, exposure time, curie, ASME V.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Bangunan Kapal > D4 Teknik Pengelasan
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 25 Aug 2018 02:28
Last Modified: 25 Aug 2018 02:28
URI: http://repository.ppns.ac.id/id/eprint/76

Actions (login required)

View Item View Item