Yosnadianti, Firoh (2016) ANALISA PERFORMA HIGH PRESSURE HEATER (HPH) #1 UNIT 2 PADA KONDISI OPERASIONAL NORMAL DENGAN METODE LOG MEAN TEMPERATURE DIFFERENCE (LMTD) DI PLTU 1 JAWA TIMUR, PACITAN. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.
Full text not available from this repository.Abstract
ABTRAK High Pressure Heater merupakan salah satu komponen penting pendukung sistem Pembangkit Listrik Tenaga Uap (PLTU). Komponen ini berperan dalam meningkatkan efisiensi energi kalor siklus secara keseluruhan dengan memanfaatkan uap ekstraksi dari High Pressure Turbin dan juga Intermediete Pressure Turbin. Salah satu fungsi High Pressure Heater adalah meningkatkan efisiensi penggunaan bahan bakar batu bara. Prinsip kerjanya adalah memanaskan air umpan boiler (feedwater) sebelum masuk ke economizer menggunakan extraction steam yang berasal dari HP Turbin dan IP Turbin yang sebelumnya telah dipanasi pada komponen Low Presure Heater. Mengingat pentingnya fungsi dari High Pressure Heater bagi penggunaan bahan bakar dan juga efisiensi panas siklus secara keseluruhan, maka dilakukan perhitungan terhadap performa perpindahan panas High Pressure Heater #1 dengan menggunakan metode Log Mean Temperature Difference (LMTD) untuk optimalisasi penggunaanya. Setelah dilakukan perhitungan perpindahan panas dari High Pressure Heater #1 dengan cara membandingkan perhitungan setelah penggunaannya beberapa tahun dengan kondisi operasional awal garansi yang dijadikan sebagai patokan data standar, maka diketahui performanya. Performa High Pressure Heater jika dilihat dari nilai LMTD, perpindahan panas maupun pressure drop nya masih dalam kondisi yang baik, meskipun terdapat penurunan. Nilai perpindahan panas yang terjadi jika dibandingkan dengan kondisi garansi untuk setiap tahunnya adalah turun 8,35% di tahun 2014, naik 5,46% di tahun 2015 , dan turun 6,84% di tahun 2016. Penurunan ini salah satunya disebabkan karena adanya faktor pengotoran pada HPH #1. Namun yang menjadi penyebab dominan turunnya performa HPH #1adalah terjadinya penurunan beban listrik yang dihasilkan sistem pembangkit. Apabila terjadi penurunan nilai performa selama penggunaan secara terus menerus di tahun berikutnya, maka penurunan nilai tersebut dapat dijadikan indikasi awal untuk perbaikan (overhaul) High Pressure Heater #1. Kata kunci : Heat Exchanger, High Pressure Heater, Shell and Tube Performa High Pressure Heater, Perpindahan Panas. ABSTRACT High Pressure Heater is one of the essential components of the supporting system of a steam power plant. This component was instrumental in improving the energy efficiency of heat cycle as a whole by utilizing extraction steam from the High Pressure Turbine and Intermediete PressureTurbine. One of the functions of High Pressure Heater is to improve the efficiency of fuel coal consumption. The principle works is heating the boiler feedwater before entering the economizer using extraction steam derived from HP Turbine and IP Turbine which had been heated in the Low Presure Heater components. Given the importance of the function of High Pressure Heater for fuel consumption and also the efficiency of the heat cycle as a whole, then the calculation is done against the heat transfer performance of High Pressure Heater #1 by using the Log Mean Temperature Difference (LMTD) method for optimization of its use. After calculating the heat transfer from the High Pressure Heater # 1 by comparing the user accounts after several years with initial operating guarantee conditions that serve as a benchmark standard data, then known the performance. The performance of High Pressure Heater if viewed from the LMTD, heat transfer and pressure drop is still in good condition, although there was a decrease. The values of heat transfer rate when it compared with the guanrantee conditions for each year is 8,35% decrease in 2014, 5,46% increase in 2015, and 6,84% decrease in 2016. This decline in one of them caused due to the fouling factor on HPH #1. However, the dominant cause of the decline in the performance of HPH #1 is decline a load of electricity generated by the power plant system. If there is a decline in performance during continuous use over the next year, so the decrease of the value can be early indication for repair (overhaul) High Pressure Heater # 1. Keywords : Heat Exchangers, High Pressure Heater, Shell and Tube Performance of High Pressure Heater, Heat Transfer.
Item Type: | Thesis (Diploma) |
---|---|
Subjects: | T Technology > T Technology (General) |
Divisions: | Jurusan Teknik Permesinan Kapal > D3 Teknik Permesinan Kapal |
Depositing User: | Unnamed user with email repository@ppns.ac.id |
Date Deposited: | 14 Sep 2018 06:37 |
Last Modified: | 14 Sep 2018 06:37 |
URI: | http://repository.ppns.ac.id/id/eprint/735 |
Actions (login required)
View Item |