PERANCANGAN MANUAL CLEAN AGENT FIRE EXTINGUISHING SYSTEM YANG DILENGKAPI FITUR MONITORING INFORMASI KEBAKARAN BERBASIS SMS GATEWAY (STUDI KASUS: RUANG DATA CENTER PT PERTAMINA RU IV)

Siregar, Evans Abednego (2016) PERANCANGAN MANUAL CLEAN AGENT FIRE EXTINGUISHING SYSTEM YANG DILENGKAPI FITUR MONITORING INFORMASI KEBAKARAN BERBASIS SMS GATEWAY (STUDI KASUS: RUANG DATA CENTER PT PERTAMINA RU IV). Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK PT. Pertamina RU IV merupakan unit pengolahan kilang terbesar di Indonesia. PT. Pertamina memiliki ruang data center yang berisi peralatan teknologi informasi dimana memuat database sebagai tempat menyimpan segala informasi penting perusahaan. Dikarenakan dalam ruangan tersebut terdapat rangkaian listrik dan berpotensi kebakaran yang menyebabkan kerusakan terhadap benda-benda berharga dan penting yang ada maka diperlukan perancangan sistem untuk menanggulangi kebakaran dan meminimalisir dampak kebakaran yang terjadi. Fasilitas data center tersebut belum dilengkapi dengan sarana proteksi kebakaran. Dalam perancangan clean agent fire extinguishing system ini, terlebih dahulu menentukan hazard volume yang akan diproteksi. Kebutuhan clean agent FM-200 ditentukan dengan membagi hazard volume dengan specific vapor volume dan mengalikan dengan konsentrasi volume FM-200, dimana total kebutuhan FM-200 akan menjadi acuan dalam menentukan tabung penyimpan, ukuran pipa dan jumlah nozzle. Semua peralatan seperti tabung penyimpan, audible alarm, visual alarm, abort switch, maintenance switch, TPM, dan aktuator terintegrasi dalam satu sistem yang diatur oleh fire control panel. Simulasi informasi kebakaran berbasis SMS Gateway dibuat untuk memberikan informasi kebakaran secara cepat dan tepat ketika asap dideteksi oleh detektor. Simulasi dibuat menggunakan smoke detector yang diintergrasikan dengan Arduino Uno R3 serta Modem GSM Wavecom Fastrack. Dari perhitungan yang dilakukan, kebutuhan FM-200 di ruang data center untuk melakukan proses pemadaman total flooding yaitu sebesar 45,53 kg, membutuhkan 1 buah tabung penyimpan berukuran 125 lb (56,5 kg), 1 buah smoke detector dan 1 buah nozzle. Informasi kebakaran secara otomatis ditujukan kepada pihak-pihak bertanggung jawab di perusahaan melalui short message service (SMS) pada saat api terdeteksi detektor. Kata kunci : Clean agent fire extingushing system, FM-200, Arduino Uno, SMS Gateway ABSTRACT PT. Pertamina RU IV is the largest refinery processing unit in Indonesia. The company owns the data center space that contains the information technology equipment which contains the database as a place to store all important company information. Because in the room there electrical circuits and potentially a fire that caused damage to valuables and important that there is then necessary to design a system to suppress fires and minimize the impact of fires. The data center facility is not equipped with the means of fire protection. In order to design clean agent fire extingushing system, the first thing to do is determine the hazard volume that will be protected . Requirement of clean agent FM - 200 is determined by dividing the volume by the specific hazard vapor volume and multiplying by the volume concentration of FM-200, where the total requirement of FM - 200 will become a reference in determining the cylinder storage, nominal pipe size and the number of nozzles. All equipment such as cylinder storage, audible alarm, visible alarm, abort switches, maintenance switches, pull station , and actuator are integrated into one system that is managed by the fire control panel . Simulation -based fire information SMS Gateway is designed to give quick and accurate fire when smoke is detected by a detector. Simulations created using the smoke detector is integrated in the Arduino Uno R3 and Wavecom Fastrack GSM Modem. Based on calculation, total needed of FM-200 in data center to do total flooding clean agent fire extingushing system are 45,53 kg, and need cylinder storage 125 lb (56,5 kg), 1 smoke detector, 1 nozzle. The information about fire is automatically sent SMS to person who take a responsbility when fire detected by smoke detector Keywords: Clean agent fire extingushing system, FM-200, Arduino Uno, SMS Gateway

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: ?? tkdkk ??
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 14 Sep 2018 02:43
Last Modified: 14 Sep 2018 02:43
URI: http://repository.ppns.ac.id/id/eprint/670

Actions (login required)

View Item View Item