DESAIN ULANG TEMPAT PENYIMPANAN BAHAN KIMIA DAN MIXING ROOM DI PT.X

Andriani, Tiya Erliana (2016) DESAIN ULANG TEMPAT PENYIMPANAN BAHAN KIMIA DAN MIXING ROOM DI PT.X. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK PT.X merupakan perusahaan yang salah satu hasil produksinya adalah ujung spidol. Bahan baku yang digunakan sebagian besar bahan kimia mudah terbakar. Sehingga perlu penanganan khusus untuk meminimalkan risiko yang ditimbulkan. PT.X memiliki mixing room yang digunakan untuk menyimpan bahan kimia sekaligus sebagai ruang untuk mencampur bahan kimia dan tempat penyimpanan yang digunakan untuk menyimpan bahan kimia yang sudah tidak bisa ditampung di mixing room. Bahan kimia yang digunakan berjumlah 12 bahan kimia yang memiliki berbagai karakteristik. Pada PT.X penyimpanan bahan kimia belum mengacu pada standard OSHA dan UNEP, penempatan yang ada saat ini hanya sebatas penyimpanan tanpa mempertimbangkan pengelompokan bahan kimia berdasarkan karakteristiknya, selain itu terdapat label dan simbol yang tidak sesuai dengan PERMENLH No.3 Tahun 2008. Tujuan dari penelitian ini adalah melakukan peninjauan ulang JHA(Job Hazard Analysis) dan desain ulang untuk tata letak tempat penyimpanan dan mixing room ke area lain, disertai dengan sistem pencegahan kebakaran yaitu APAR dan detektor serta kebutuhan penerangan dan ventilasi. Penelitian dimulai dengan pengambilan data bahan kimia dan kuantitasnya, Material Safety Data Sheet (MSDS), lay out mixing room dan tempat penyimpanan yang lama maupun yang baru, dan JHA pada area tersebut. Kemudian melakukan peninjauan JHA, memberi label dan simbol, mengelompokkan bahan kimia berdasarkan karakteristiknya dan menentukan penempatannya dengan compatibility chart. Setelah itu, dilakukan perhitungan kebutuhan dan jenis detektor, APAR, penerangan dan ventilasi. Dari hasil penelitian yang telah dilakukan, rekomendasi yang diberikan yaitu, pemberian simbol dan label. Penempatan bahan kimia berdasarkan karakteristiknya. Terdapat 3 area penyimpanan, mixing room terdapat tiga bahan yang disimpan, lima bahan untuk tempat penyimpanan 1 dan empat bahan tempat penyimpanan 2. APAR yang dibutuhkan adalah satu buah dengan jenis dry chemical, CO2, ataupun foam dan dibutuhkan satu buah detektor untuk tiap ruangan dengan jenis heat detektor. Penerangan yang dibutuhkan tiga armatur untuk tempat penyimpanan 1 dan masing-masing satu armatur untuk tempat penyimpanan 2 dan mixing room. Exhaust fan yang dibutuhkan satu buah untuk tempat penyimpanan 2 dan mixing room, dua buah untuk tempat penyimpanan 1. Kata kunci: B3, JHA, Compatibility Chart, Exhaust Fan ABSTRACT PT.X is a company that one of their products is the tip markers. Raw materials used are mostly flammable chemicals. So that needs special handling to minimize the risk posed. PT.X has a mixing room used for storing chemicals as well as a space for mixing the chemicals and storage area used to store chemicals that can not be accommodated in the mixing room. The chemicals used were 12 chemicals that have various characteristics. In the chemical storage PT.X not comply with the OSHA standard and UNEP, the placement of which there is currently only limited storage without considering grouping chemicals based on their characteristics, besides there are labels and symbols that are not in accordance with PERMENLH 3, 2008. The purpose of this study is to review the JHA (Job Hazard Analysis) and redesigned the layout of storage and mixing room to other areas, accompanied by a fire prevention system that is APAR and detectors as well as lighting and ventilation needs. The study began with data collection and quantity of chemicals, Material Safety Data Sheet (MSDS), lay out the mixing room and a storage area that is old and new, and JHA in these areas. Then conduct a review of JHA, labeling and symbols, classifying chemicals according to their characteristics and determine its placement with compatibility chart. After that, the calculation needs and the type of detector, fire extinguisher, lighting and ventilation. From the research that has been done, the recommendations given, namely, the provision of symbols and labels. Placement of chemicals based on their characteristics. There are 3 areas of storage, mixing room there are three materials that are stored, five materials for first storage and four materials for second storage. APAR takes is one piece with the type of dry chemical, CO2, or foam and the detectors needed for each room with type heat detectors. Illumination takes three armature for first storage and each one armature for second storage and mixing room. Exhaust fan takes one piece for both storage and mixing room, two for the first storage area. Keywords: B3, JHA, Compatibility Chart, Exhaust Fan

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: ?? tkdkk ??
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 13 Sep 2018 05:09
Last Modified: 13 Sep 2018 05:09
URI: http://repository.ppns.ac.id/id/eprint/637

Actions (login required)

View Item View Item