DESAIN JALUR PIPA ALTERNATIF UNTUK MENGALIRKAN LIMBAH DARI CONDENSATE TANK MENUJU CEMENT JETTY DI PT. PHE WMO

Farhana, Ariesta Dhani (2015) DESAIN JALUR PIPA ALTERNATIF UNTUK MENGALIRKAN LIMBAH DARI CONDENSATE TANK MENUJU CEMENT JETTY DI PT. PHE WMO. Diploma thesis, POLITEKNIK PERKAPALAN NEGERI SURABAYA.

Full text not available from this repository.

Abstract

ABSTRAK PT. PHE WMO merupakan salah satu perusahaan oil and gas yang terletak di Gresik. Proses produksi menghasilkan limbah berwujud air dan minyak. Limbah ditampung di condensate tank. Limbah dialirkan dari condensate tank menuju cement jetty. Permasalahan yang terjadi adalah jalur perpipaan untuk mengalirkan limbah berada diluar wilayah Pertamina, waktu pengosongan tangki terlalu lama dan jalur pipa tidak mengacu pada standar sehingga diperlukan redesain jalur perpipaan. Pada Tugas Akhir ini, akan mendesain jalur pipa alternatif untuk mengalirkan limbah dari condensate tank menuju cement jetty sesuai standar ASME B31.3. perhitungan desain yang dilakukan seperti : perhitungan diameter pipa, perhitungan ketebalan minimum pipa, perhitungan headloss, perhitungan daya pompa dan perhitungan jarak span pipa. Dalam tugas akhir ini juga dilakukan desain support yang akan digunakan. Hasil desain menunjukkan bahwa spesifikasi teknis pipa yang digunakan adalah NPS 6 sch STD dengan jenis material SA-106 Gr.B. Jenis fitting yang digunakan dalam desain adalah SA-234 Gr.WPB. Support yang digunakan adalah pipe support with U-Bolt. Span pada pipa horizontal tanpa fitting dalam desain ini sebesar 12,94 m. Jika terdapat fitting diantara 2 titik support maka maximum span yang digunakan sebesar 9,84 m. Daya pompa yang dibutuhkan dalam desain ini sebesar 90,86 kW. Kata kunci : Jalur pipa alternatif, Detail desain, Maximum span, Support, Daya pompa ABSTRACT PT. PHE WMO is one of the oil and gas company located in Gresik. The production process produce waste tangible water and oil. Waste collected in the condensate tank. Waste flowed from the condensate tank to cement jetty. The problem that occurs is to line pipes to flow waste located outside the area of Pertamina, time to emptying the tank too long and line pipes does not refer to the standard that is required redesign of line pipes. In this final project, will be design alternative line pipes to flow waste from condensate tank to cement jetty appropriate to the standard ASME B31.3. design calculation are performed such as : pipe diameter calculation, calculation of minimum thickness of the pipe, headloss calculation, calculation of power pumps and pipes span distance calculation. In this final project was also performed design support that will be used. The results showed that the design of the technica specifications of the pipe used is NPS 6 sch STD with the type of material SA-106 Gr.B. Type of fitting used in design is SA-234 Gr.WPB. the support used is a support pipe with U-Bolt. Span in the horizontal pipes without fittings in this design at 12,94 m. If there is a fitting between the two points of support, the maximum span of 9,84 m were used. Required pump power of this design is 90,86 kW. Keyword : Line pipes alternative, Detai design, Maximum span, Support, Power pump

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
Divisions: Jurusan Teknik Permesinan Kapal > D4 Teknik Perpipaan
Depositing User: Unnamed user with email repository@ppns.ac.id
Date Deposited: 10 Sep 2018 04:19
Last Modified: 10 Sep 2018 04:19
URI: http://repository.ppns.ac.id/id/eprint/485

Actions (login required)

View Item View Item